Bolted circular flange connections under static bending moment and axial force
نویسندگان
چکیده
منابع مشابه
Elastic-Plastic Analysis of Bending Moment – Axial Force Interaction in Metallic Beam of T-Section
This study derives kinematic admissible bending moment – axial force (M-P) interaction relations for mild steel by considering elastic-plastic idealizations. The interaction relations can predict strains, which is not possible in a rigid perfectly plastic idealization. The relations are obtained for all possible cases pertaining to the locations of neutral axis. One commercial rolled steel T-se...
متن کاملQuasi-static Axial Compression of thin-walled Circular Composite Tubes
Assessing the behavior of composite structures which are subjected to impact loads is one of the important subjects in the field of mechanical sciences. Using thin-walled tubes which collapsed and absorbed the impact energy is a well-known method to prevent damages to the other parts of the structures. In this paper, deformations, crushing length, peak load, mean force and energy absorption cap...
متن کاملOPTIMAL DESIGN OF COLUMNS FOR AN INTERMEDIATE MOMENT FRAME UNDER UNIAXIAL MOMENT AND AXIAL LOADS
The present study addresses optimal design of reinforced concrete (RC) columns based on equivalent equations considering deformability regulations of ACI318-14 under axial force and uniaxial bending moment. This study contrary to common approaches working with trial and error approach in design, at first presents an exact solution for intensity of longitudinal reinforcement in column section by...
متن کاملBolted moment connections in drive-in and drive-through steel storage racks
Often unbraced, the stability of steel storage racks may depend solely on the pallet beam to upright connector and on the stiffness of the base plate to floor connection ([1]). This paper presents experimental results from cyclic tests performed on portal beam to upright bolted moment connections intended for cold-formed steel drive-in and drive-through storage racks. In storage racks, portal b...
متن کاملEffect of cantilever length and inclined implants on axial force and bending moment in implant-supported fixed prostheses
Methods: Ten metallic bars simulated frameworks of fixed implant-supported prosthesis over two master models with five implants: one with all implants straight and parallel (n=5) and one with the two distal implants tilted (n=5). Strain gauges were fixed on abutments to measure deformation when a 50N-load was applied on the cantilever at 10, 15, and 20 mm-distance from the distal abutment. Defo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Constructional Steel Research
سال: 2019
ISSN: 0143-974X
DOI: 10.1016/j.jcsr.2018.12.024