Bending Performance of Precast Ceramsite-Concrete-Insulated Sandwich Panel with Stainless Steel Shear Connectors

نویسندگان

چکیده

With the continuous improvement of building energy-conservation requirements, both traditional concrete external insulation and internal have been unable to meet energy-saving needs. In order demands in new era, precast external-wall-insulation technology should be developed. this study, a bending static test numerical simulation were carried out evaluate influence thickness inner wythe length plate-type shear connectors on cracking condition, bearing capacity composite degree ceramsite-concrete-insulated sandwich panel (PCCISP) under outside-plane load. The results show that failure modes four panels all ductile flexural members. ultimate PCCISP decreased with decrease wythe. Reducing had no significant capacity. When was reduced by 30%, rigidity increased 8.85% 2.67%, respectively. Increasing connector slightly capacity, but it obvious degree.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Composite Behavior of a Novel Insulated Concrete Sandwich Wall Panel Reinforced with GFRP Shear Grids: Effects of Insulation Types

A full-scale experimental program was used in this study to investigate the structural behavior of novel insulated concrete sandwich wall panels (SWPs) reinforced with grid-type glass-fiber-reinforced polymer (GFRP) shear connectors. Two kinds of insulation-expanded polystyrene (EPS) and extruded polystyrene (XPS) with 100 mm thickness were incased between the two concrete wythes to meet the in...

متن کامل

Designing a prefabricated sandwich composite roofing system Made up of resisting facings and light-weight concrete core with truss-shaped connectors

In this paper, a new roofing system is introduced, which is constructued using the precast composite sandwich panels. This roofing sandwich panels system consists of three kinds of precast concrete sandwich panels including capital panels, beam or between columns panels, and slab or middle panels. The panels are composed of three layers; A high strength reinforced concrete top layer. A thick la...

متن کامل

Behavior of Steel–Concrete Composite Beams with Corroded Shear Studs Under Negative Bending Moment

The behavior of corroded steel–concrete composite beams under hogging moment was studied by experimental investigation and theoretical analysis. A total of eight specimens, six of which had corroded shear studs, were tested. The corrosion rate of studs ranged from 0 to approximately 50%. The constant-current accelerated corrosion method was adopted to accelerate the corrosion process. The loadi...

متن کامل

Experimental Study on Mechanical Behavior of Shear Connectors of Square Concrete Filled Steel Tube

In order to quantitatively evaluate the shear-bearing capacity of shear connectors of square concrete filled steel tube (CFST), push-out tests on 14 square CFSTs with shear connectors have been carried out. Among the 14 CFSTs, there are 13 specimens with steel plate connectors and one specimen with steel bar connectors. The following factors are investigated to figure out their influences on th...

متن کامل

Seismic Performance of Steel Plate-Reinforced Concrete Composite Shear Wall

In tall buildings the reinforced concrete (RC) shear wall is one of the predominant structural components used to resist lateral loads induced by earthquakes around the world. Previous research demonstrated that shear walls displayed a sudden loss in lateral capacity due to the wall corner and web crushing in the plastic zone. In addition, it was found that large shear distortions in shear wall...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Buildings

سال: 2022

ISSN: ['2075-5309']

DOI: https://doi.org/10.3390/buildings12101640