Bandgaps and Surface Inter-Band States in Photocatalysts with High Energy Resolution EELS
نویسندگان
چکیده
منابع مشابه
Exploring Phonon Signals by High Energy / High Spatial Resolution EELS
1 Nion Co., 1102 Eight St, Kirkland, WA 98033, USA 2 Center for Solid State Science, Arizona State University, Tempe, AZ 85287, USA 3 Department of Chemistry and Biochemistry, Arizona State University, Tempe, AZ 85287, USA 4 School for Engineering of Matter, Transport and Energy, ASU, Tempe, AZ 85287, USA 5 Department of Physics, ASU, Tempe, AZ 85287, USA 6 Department of Physics, University of ...
متن کاملHigh resolution EELS using monochromator and high performance spectrometer: comparison of V2O5 ELNES with NEXAFS and band structure calculations.
Using single crystal V2O5 as a sample, we tested the performance of the new aberration corrected GATAN spectrometer on a monochromatised 200 kV FEG FEI (S)TEM. The obtained V L and O K ELNES were compared with that obtained in a common GATAN GIF and that in the new spectrometer, without monochromatised beam. The performance of the new instrumentation is impressive: recorded with an energy-resol...
متن کاملHigh Resolution Optical and Vibrational Spectroscopy with Low Loss EELS
Despite being diffraction limited to thousands of Ångstroms, infrared and optical spectroscopies remain effective characterization techniques. While it is possible to perform subatomic resolution electron energy loss spectroscopy (EELS) at unprecedented energy resolution, with ever improving aberration correctors and monochromators, it is argued that low loss features can be severely delocalize...
متن کاملProspects for vibrational-mode EELS with high spatial resolution.
Taking advantage of previous measurements by Geiger and co-workers, we discuss the possibilities and problems of measuring vibrational modes of energy loss in a transmission electron microscope fitted with a monochromator and a high-resolution energy-loss spectrometer. The tail of the zero-loss peak is seen to be a major limitation, rather than its full-width at half-maximum. Because of the low...
متن کاملEELS at very high energy losses.
Electron energy-loss spectroscopy (EELS) has been investigated in the range from 2 to >10 keV using an optimized optical coupling of the microscope to the spectrometer to improve the high loss performance in EELS. It is found that excellent quality data can now be acquired up until about 5 keV, suitable for both energy loss near edge structure (ELNES) studies of oxidation and local chemistry, a...