b matrix errors in echo planar diffusion tensor imaging
نویسندگان
چکیده
منابع مشابه
b matrix errors in echo planar diffusion tensor imaging
Diffusion-weighted magnetic resonance imaging (DW-MRI) is a recognized tool for early detection of infarction of the human brain. DW-MRI uses the signal loss associated with the random thermal motion of water molecules in the presence of magnetic field gradients to derive parameters that reflect the translational mobility of the water molecules in tissues. If diffusion-weighted images with diff...
متن کاملThe b matrix in diffusion tensor echo-planar imaging.
In diffusion tensor imaging (DTI) an effective diffusion tensor in each voxel is measured by using a set of diffusion-weighted images (DWIs) in which diffusion gradients are applied in a multiplicity of oblique directions. However, to estimate the diffusion tensor accurately, one must account for the effects of all imaging and diffusion gradient pulses on each signal echo, which are embodied in...
متن کاملHow to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging.
Diffusion tensor imaging is often performed by acquiring a series of diffusion-weighted spin-echo echo-planar images with different direction diffusion gradients. A problem of echo-planar images is the geometrical distortions that obtain near junctions between tissues of differing magnetic susceptibility. This results in distorted diffusion-tensor maps. To resolve this we suggest acquiring two ...
متن کاملA tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging
The development of accurate, non-invasive methods for mapping white matter fiber-tracts is of critical importance. However, fiber-tracking is typically performed on diffusion tensor imaging (DTI) data obtained with echo-planar-based imaging techniques (EPI), which suffer from susceptibility-related image artifacts, and image warping due to eddy-currents. Thus, a number of white matter fiber-bun...
متن کاملIn vivo diffusion tensor imaging of rat spinal cord with echo planar imaging.
The in vivo apparent diffusion tensor (ADT) of spinal cord was measured in nine rats at 2.0 T using an interleaved multi-shot echo planar imaging (EPI) diffusion sequence. A technique that combines sliding acquisition and phase correction, based on a calibration scan, to reduce ghosting artifacts in the images introduced by the strong diffusion-sensitizing gradients was described. Two rotationa...