Awake Intubation - Videolaryngoscope or Fibreoptic Scope?

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Awake fibreoptic intubation for airway burns.

A young adult was admitted to a casualty department with severe burns sustained in a motor vehicle fire. His airway was initially patient, but in grave danger of obstruction due to inhalational injury. Conventional methods of airway management were unable to guarantee a patent airway and a novel approach is described.

متن کامل

Fibreoptic awake intubation--a method of topical anaesthesia and orotracheal intubation.

Three cases of trismus caused by oropharyngeal sepsis are described where fibreoptic-assisted awake intubation using an oral airway intubator and nebulised lidocaine was safely and successfully achieved.

متن کامل

Videolaryngoscope-Assisted Fibreoptic Tracheal Intubation in a Young Adolescent with Hunter Syndrome for Posterior Cervical Fusion

We here describe a videolaryngoscope assisted fibreoptic tracheal intubation in a 17-year-old patient with Hunter Syndrome (Mucopolysaccharidosis Type II) and known difficult intubation who required posterior cervical fusion surgery for cervical canal stenosis. The patient had a history of failed nasal and oral fibreoptic intubation. The use of a videolaryngoscope enabled continuous visualizati...

متن کامل

GlideScope videolaryngoscope versus flexible fiberoptic bronchoscope for awake intubation of morbidly obese patient with predicted difficult intubation.

BACKGROUND Awake fiberoptic intubation is the gold standard for management of predicted difficult intubation. The purpose of this study was to test whether Glide Scope video laryngoscopy (GVL) will provide significant advantages over fiberoptic bronchoscopy (FOB) for awake intubation in morbidly obese patients with predicted difficult intubation. We therefore tested the hypothesis that intubati...

متن کامل

Pentax-AWS videolaryngoscope for awake nasal intubation in patients with unstable necks.

In patients with unstable necks and at risk of pulmonary aspiration, awake fibreoptic intubation is often appropriate. However, stabilization of the neck can make fibreoptic intubation more difficult. I report the use of awake nasal intubation using the Pentax-Aiway Scope (AWS) in three patients with restricted neck movement, in whom awake fibreoptic intubation had failed. Case 1: a 59-yr-old m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Anesthesia & Clinical Research

سال: 2011

ISSN: 2155-6148

DOI: 10.4172/2155-6148.1000102e