Automated Cerebrospinal Fluid Cell Counts Using the Sysmex XE-5000
نویسندگان
چکیده
منابع مشابه
Evaluation of pleural and ascitic fluid analysis on the Sysmex XE-5000 hematology analyzer
Introduction: Body fluid (BF) analysis is critical to the diagnosis and monitoring of several pathological conditions. The limitations of manual cell counts have led to greater interest in the development of automated BF analysis. Objective: To evaluate the analytical performance of the Sysmex XE-5000 hematology analyzer in the analysis of pleural and ascitic fluids in the laboratory routine of...
متن کاملValidation of Gating and Leukocyte Classification on Sysmex XE Series Automated Cell Counters
− 1 − Leukocyte classification on Sysmex XE series hematology analyzers involves staining leukocytes with proprietory Polymethine Dye reagents that have affinity for nucleic acids. The outputs are two-dimensional scatter diagrams of side scatter and fluorescence intensity (DIFF scattergrams) subsequent to flow cytometric analysis of the stained cells. Leukocyte classification is based on the lo...
متن کاملDo the flags related to immature granulocytes reported by the Sysmex XE-5000 warrant a microscopic slide review?
OBJECTIVES The Sysmex XE-5000 instruments (Sysmex, Kobe, Japan) count immature granulocytes (IGs) and use the "Imm Gran?" flag to signal unreliable results. This study investigated the usefulness of the "Imm Gran?" flag and the analytical and diagnostic performance of the IG measurements in a side-by-side evaluation. METHODS In total, 408 samples were analyzed on three XE-5000 instruments. Th...
متن کاملPerformance evaluation of the immature granulocyte parameter on the Sysmex XE-2100 automated hematology analyzer.
Recently, St. Anthony's Medical Center Laboratory (SAMC) in St. Louis, Missouri, installed a new automated hematology analyzer, the Sysmex XE-2100. The XE-2100 has an additional differential parameter, the immature granulocyte (IG) parameter. Prior to implementation, the IG parameter was evaluated by comparison to the manual immature granulocyte count. Immature granulocytes counted manually, as...
متن کاملComparison of automated differential blood cell counts from Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in normal and pathologic samples.
Reliable automated blood cell characterization and quantification remain challenging in pathologic samples, whereas slide reviews due to unnecessary flagging should be avoided. We compared 4 modern hematology analyzers-Abbott Sapphire, Siemens Advia 120, Sysmex XE-2100, and Beckman Coulter DxH 800-regarding complete blood cell count (CBC), leukocyte differential count, and flagging efficacy in ...