Assessment of optimal stent implantation using computerized pressure-volume curves
نویسندگان
چکیده
منابع مشابه
assessment of the efficiency of s.p.g.c refineries using network dea
data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...
Pressure-volume curves of the respiratory system.
The quasi-static pressure-volume (P-V) curve of the respiratory system describes the mechanical behavior of the lungs and chest wall during inflation and deflation. To eliminate resistive and convective acceleration effects, the measurement of volume and pressure must be performed during short periods of apnea or during very slow flow. There are 3 main techniques for acquiring quasi-static P-V ...
متن کاملOptimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique
Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...
متن کاملSafety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملOptimal implantation strategies using drug-eluting stents for in-stent restenosis: do we know the answer?
Drug-Eluting Stents for In-Stent Restenosis: Do We Know the Answer? To the Editor: We read with great interest the elegant but provocative study of Fujii et al1 assessing mechanisms of drug-eluting stent (DES) failure in patients treated for in-stent restenosis (ISR). Focal recurrence after DES treatment occurred in 25% of patients. Eleven patients with ISR recurrence showed evidence of severe ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the American College of Cardiology
سال: 1998
ISSN: 0735-1097
DOI: 10.1016/s0735-1097(98)80725-0