Assessment of central corneal thickness and corneal endothelial morphology using ultrasound pachymetry, non-contact specular microscopy, and Confoscan 4 confocal microscopy

BACKGROUND The aim was to compare the repeatability, reproducibility and inherent precision of ultrasound pachymetry (USP), noncontact specular microscopy (SP-2000P) and the Confoscan 4 confocal microscope (z-ring CS4) in measuring endothelial cell density (ECD), coefficient of variation of cell size (CV), and central corneal thickness (CCT) in normal eyes. METHODS In this prospective study, ...

متن کامل

Central corneal thickness: z-ring corneal confocal microscopy versus ultrasound pachymetry.

PURPOSE To compare the repeatability and validity of corneal pachymetry by a corneal confocal microscope with a z-axis adapter (Confoscan 4.0 with z-ring adapter: z-CS4) versus ultrasound (US) pachymetry in the measurement of central corneal thickness (CCT). METHODS CCT in 44 eyes of 44 subjects was determined with z-CS4. Z-CS4 exams were used to estimate the repeatability of thickness measur...

متن کامل

Comparison of central corneal thickness estimated by an ultrasonic pachymeter and non-contact specular microscopy.

Purpose: To compare central corneal thickness (CCT) measurements of healthy individuals obtained with ultrasonic pachymetry (UP) and non-contact specular microscopy (NCSM). Method: In total, 148 eyes of 74 subjects with no ocular or systemic diseases were included in the study. Central corneal thickness measurements of all patients performed with UP and NCCM were compared. Results: A total ...

متن کامل

Comparison of central corneal thickness: ultrasound pachymetry versus slit-lamp optical coherence tomography, specular microscopy, and Orbscan

BACKGROUND Central corneal thickness (CCT) can be measured by using contact and non-contact methods. Ultrasound pachymetry (US pachymetry) is a contact method for measuring CCT and is perhaps the most commonly used method. However, non-contact methods like scanning slit topography (Orbscan II), slit-lamp optical coherence tomography (SL-OCT), and specular microscopy are also used. Not many stud...

متن کامل

Comparison of Central Corneal Thickness Measurement Using Non-Contact and Contact Pachymetry Devices in Normal Eyes

Materials and Methods: This prospective, cross sectional comparative study evaluated 30 healthy subjects fulfilling the inclusion criteria reporting in AFIO Rawalpindi. CCT was measured in both eyes of subjects using noncontact specular microscope, Dual Scheimpflug analyzer and contact ultrasound pachymeter by a single investigator at the same time of the day. Pearson’s correlation coefficient ...