3d Catenary Curve Fitting for Geometric Calibration
In modern road surveys, hanging power cables are among the most commonly-found geometric features. These cables are catenary curves that are conventionally modelled with three parameters in 2D Cartesian space. With the advent and popularity of the mobile mapping system (MMS), the 3D point clouds of hanging power cables can be captured within a short period of time. These point clouds, similarly...
متن کاملA Curve-fitting Calibration Method applied for Ultrasonic Flow-meter
As the influence of fluid distribution in the internal pipe, the measurement characteristics of theory and practice exist significant differences in Ultrasonic Flow-meter (USF). Through analysis of fluid state, the method of curve-fitting is applied for the calibration of USF. Experimental results show that the USF can achieve level-1 accuracy with just a correction of 5 flow points, and this m...
متن کاملMiniaturized ligand-binding assays: theoretical considerations
Markus F. Templin Dieter Stoll Monika Schrenk Petra C. Traub Christian F. Vöhringer and Thomas O. Joos* NMI Natural and Medical Sciences Institute at the University of Tübingen, Markwiesenstr. 55, 72770 Reutlingen, Germany. *e-mail: [email protected] The fundamental principles of miniaturized and parallelized microspot ligand-binding assays were described more than a decade ago. In the ‘ambient analy...
متن کاملSignal detection Using Rational Function Curve Fitting
In this manuscript, we proposed a new scheme in communication signal detection which is respect to the curve shape of received signal and based on the extraction of curve fitting (CF) features. This feature extraction technique is proposed for signal data classification in receiver. The proposed scheme is based on curve fitting and approximation of rational fraction coefficients. For each symbo...
متن کاملCurve Fitting and Polymers
1 Curve Fitting and Polymers The availability of data from well-characterized samples such as those offered by Beamson and Briggs [1] owe much to the popularity of XPS as a tool for understanding the chemistry of polymers. A typical C 1s envelope [2] (Figure 1) includes structure that offers chemical information about a sample, but without some initial starting point it is difficult to construc...