Application of positive end expiratory pressure during laparoscopic surgery
نویسندگان
چکیده
منابع مشابه
Application of positive end expiratory pressure during laparoscopic surgery
provided the original work is properly cited. CC Positive-pressure ventilation during general anesthesia is a prerequisite for numerous surgical conditions. Mechanical ventilation is non-physiological and can induce lung injury, although ventilator-induced lung injury may be of minor clinical importance during anesthesia for most patients with healthy lungs. However, growing evidence suggests t...
متن کاملAirway mechanosensor behavior during application of positive end-expiratory pressure.
BACKGROUND Positive end-expiratory pressure (PEEP) is commonly used in clinical settings. It is expected to affect the input from slowly adapting pulmonary stretch receptors (SARs), leading to altered cardiopulmonary functions. However, we know little about how SARs behave during PEEP application. OBJECTIVES Our study aimed to characterize the behavior of SARs during PEEP application. METHO...
متن کاملEvaluation of low tidal volume with positive end-expiratory pressure application effects on arterial blood gases during laparoscopic surgery.
BACKGROUND Pneumoperitoneum (PNP) and patient positions required for laparoscopy can induce pathophysiological changes that complicate anesthetic management during laparoscopic procedures. This study investigated whether low tidal volume and positive end-expiratory pressure (PEEP) application can improve ventilatory and oxygenation parameters during laparoscopic surgery. METHODS A total of 60...
متن کاملPositive end-expiratory pressure.
PURPOSE OF REVIEW In the last 2 years, several reports have dealt with recruitment/positive end-expiratory pressure (PEEP) selection. Most of them confirm previous results and few add new information. RECENT FINDINGS It has been definitely confirmed that opening pressures are different throughout the acute respiratory distress syndrome lung parenchyma, ranging from 5-10 up to 30-40 cmH2O. The...
متن کاملResponse of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery
Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Korean Journal of Anesthesiology
سال: 2013
ISSN: 2005-6419,2005-7563
DOI: 10.4097/kjae.2013.65.3.193