Application of high voltage electric field (HVEF) drying technology in potato chips
نویسندگان
چکیده
منابع مشابه
Electric Field Modelling of Non-Ceramic High Voltage Insulators
Electric field calculations are not common practice in the design and development of non-ceramic insulators for high voltage transmission applications. This paper applies a three-dimensional (3D) electric field analysis program to calculate the field distribution at the live-end of 275kV and 330 kV non-ceramic insulators used in the Queensland transmission system. At these voltages, fields can ...
متن کاملMicrocontroller Based High Voltage Pulse Electric Field Generator for Pasteurization
In This paper describes the design and implementation of Microcontroller based High Voltage pulse electric field generator for Liquid food pasteurization. It generates a high voltage (15 kV) approximately in the frequency range from 250 Hz to 30 kHz. This high voltage applied for food pasteurization, which is placed between two electrodes.
متن کاملdegradation of oil impregnated paper insulation under influence of repetitive fast high voltage impulses
در طی سالهای اخیراستفاده ازمنابع انرژی تجدید پذیر در شبکه های مدرن بنا به دلایل زیست محیطی و اقتصادی به طور گسترده استفاده شده است همچون نیروگاههای بادی و خورشیدی .ولتاژتولیدی این نیروگاهها اغلب به فرم dc می باشد وادوات الکترونیک قدرت به عنوان مبدل و پل بین شکل موج dc وac استفاده می شوند.این پروسه باعث ایجاد پالسهایی برروی شکل موج خروجی می شود که می تواند وارد تجهیزات قدرت همچون ترانسفورماتور ی...
15 صفحه اولPulsed Electric Field Processing in Food Technology
Pulsed electric field (PEF) processing is a emerging method of food preservation that uses short bursts of electricity for microbial inactivation (cell-lysis) and causes minimal or no detrimental effect on food quality attributes. PEF can be used for processing liquid and semiliquid food products.
متن کاملPulsed electric field reduces the permeability of potato cell wall.
The effect of the application of pulsed electric fields to potato tissue on the diffusion of the fluorescent dye FM1-43 through the cell wall was studied. Potato tissue was subjected to field strengths ranging from 30 to 500 V/cm, with one 1 ms rectangular pulse, before application of FM1-43 and microscopic examination. Our results show a slower diffusion of FM1-43 in the electropulsed tissue w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2013
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/418/1/012144