Anticoagulant properties of enoxaparin 400 IU/mL–40 % ethanol catheter lock solution
نویسندگان
چکیده
منابع مشابه
Anticoagulant properties of enoxaparin 400 IU/mL–40 % ethanol catheter lock solution
Unfractionated heparin (UFH) is the most widely used interdialytic lock solution but has no anti-infectious properties. Ethanol at a content ≥40 %v/v eradicates experimental biofilm but has no anticoagulant properties. In contrast to UFH, enoxaparin (Enox) can be combined with 40 % ethanol without precipitation. Enoxaparin 400 UI/mL-40 % ethanol (Enox/Eth) has antibiofilm properties and therefo...
متن کاملCompatibility of Injectable Anticoagulant Agents in Ethanol; In Vitro Antibiofilm Activity and Impact on Polyurethane Catheters of Enoxaparin 400 U/mL in 40% v/v Ethanol
BACKGROUND AND OBJECTIVES Interdialytic lock solutions should maintain catheter patency and prevent catheter infections. We aimed to determine in which conditions injectable anticoagulant agents (IAAs) combined with ethanol are compatible and to assess the antibiofilm activity of the selected combination and its effects on dialysis catheters (DC). METHODS The solubility and compatibility of u...
متن کاملMicrobial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens)
BACKGROUND Microbial infections are the most serious complications associated with indwelling central venous catheters. A catheter lock solution that is both antibacterial and antithrombotic is needed. The goal of this study was to determine whether a new catheter lock solution containing citrate, methylene blue and parabens has antimicrobial properties against planktonic bacteria and against s...
متن کاملAntimicrobial activity of a novel catheter lock solution.
Intravascular catheter-associated bloodstream infections significantly increase rates of morbidity and hospital costs. Microbial colonization and development of biofilms, which are known to be recalcitrant to antibiotic therapy, often lead to the loss of otherwise patent vascular access systems. We evaluated a new taurolidine- and citrate-based catheter lock solution (Neutrolin; Biolink Corpora...
متن کاملMinocycline-EDTA lock solution prevents catheter-related bacteremia in hemodialysis.
There is growing concern about the development of antibacterial resistance with the use of antibiotics in catheter lock solutions. The use of an antibiotic that is not usually used to treat other serious infections may be an alternative that may reduce the clinical impact should resistance develop. We conducted a randomized controlled trial to compare a solution of minocycline and EDTA with the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: SpringerPlus
سال: 2015
ISSN: 2193-1801
DOI: 10.1186/s40064-015-1533-2