Anti-seismic Capacity Improvement of Underground Box Structures Strengthened with Pressure Bracing
نویسندگان
چکیده
منابع مشابه
Seismic strengthening and seismic improvement of timber structures
In European seismic areas timber structures are found as building frames, in combination with masonry infills, in bridges, but most frequently in roof structures and floor slabs of traditional buildings. Seismic strengthening of existing structures should provide a well-defined and simple path to seismic forces, maintain timber members elastic, and develop as much as possible the post-elastic b...
متن کاملDiscrete-Time Modal Control for Seismic Structures with Active Bracing System
In this study, a shaking-table test was performed to verify a proposed discretetime modal control method that is suitable for seismic control of structural systems and also easy for digital control implementation. The computation of the feedback gain is formulated in a discrete-time domain and is given in a concise matrix form. A method for generating the best achievable eigenvectors that are m...
متن کاملSeismic wave interaction with underground cavities
Motivation The Comprehensive-Nuclear-Test-Ban-Treaty (CTBT) aim to prohibit any nuclear explosion on Earth. For its realization a nuclear test verification strategy has to be set up, consisting of three pillars: •Monitoring • International Data Center •On-Site Inspection (OSI) OSI aims to be the ultimate tool to clarify wether or not a nuclear test has been carried out in violation of the CTBT....
متن کاملAPPLICATION OF NEURAL NETWORK IN EVALUATION OF SEISMIC CAPACITY FOR STEEL STRUCTURES UNDER CRITICAL SUCCESSIVE EARTHQUAKES
Depending on the tectonic activities, most buildings subject to multiple earthquakes, while a single design earthquake is suggested in most seismic design codes. Perhaps, the lack of easy assessment to second shock information and sometimes use of inappropriate methods in estimating these features cause successive earthquakes mainly were ignored in the analysis procedure. In order to overcome t...
متن کاملEnergy-Based Design Criterion of Dissipative Bracing Systems for the Seismic Retrofit of Frame Structures
Direct sizing criteria represent useful tools in the design of dissipative bracing systems for the advanced seismic protection of existing frame structures, especially when incorporated dampers feature a markedly non-linear behaviour. An energy-based procedure is proposed herein to this aim, focusing attention on systems including fluid viscous devices. The procedure starts by assuming prefixed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Korean Society of Safety
سال: 2013
ISSN: 1738-3803
DOI: 10.14346/jkosos.2013.28.4.097