Analysis on Lightning Overvoltage According to Lead Length of Surge Arrester for Underground Cable Outdoor Termination Protection at C/H Tower
نویسندگان
چکیده
منابع مشابه
Improvements of an FDTD-Based Surge Simulation Code and Its Application to the Lightning Overvoltage Calculation of a Transmission Tower
This paper presents new features recently added to a general-purpose surge simulation code based on the FDTD (Finite Difference Time Domain) method. The added features include various-shape conductor models, lumped-parameter circuit-element models, a lightning-channel model, and an integrated analysis environment (IAE). For precisely modeling the shapes of various conductors, the following cond...
متن کاملSensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation
Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...
متن کاملPerformance of Surge Arrester to Multiple Lightning Strokes on Nearby Distribution Transformer
Overhead distribution lines are prone to lightning overvoltages due to their configurations and characteristics. Metal Oxide Varistor (MOVs) arresters for many years have proven to be more advantageous than others arresters in lightning surge protection; therefore it is worthwhile to continually assess the behavior and performance of these arresters to different kind of overvoltages caused by l...
متن کاملA Review of Current Issues in State-of-Art of Wind Farm Overvoltage Protection
This paper elaborates on several important outstanding issues in the state-of-art of overvoltage protection selection for modern wind farms. The lack of experience with this still-new technology, together with the inherent complexity of wind farm electrical systems, entails several unresolved issues pertinent to the topic of overvoltage protection, particularly in relation to lightning-initiate...
متن کاملMetal-oxide surge arrester model for fast transient simulations
Metal-oxide surge arresters have dynamic characteristics that are significant for overvoltage coordination studies involving fast front surges. Several models with acceptable accuracy have been proposed to simulate this frequency-dependent behavior. Difficulties arise in the calculation and adjustment of the model parameters: in some cases iterative procedures are required, in others the necess...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Transactions of The Korean Institute of Electrical Engineers
سال: 2016
ISSN: 1975-8359
DOI: 10.5370/kiee.2016.65.2.257