Analysis of Bubble Behavior in a Horizontal Rectangular Channel under Subcooled Flow Boiling Conditions
نویسندگان
چکیده
منابع مشابه
Critical heat flux in subcooled flow boiling of fluorocarbon liquid on a simulated electronic chip in a vertical rectangular channel
Experiments are performed to correlate and model CHF during subcooled flow boiling of dielectric fluoro~rbon (FC-72) liquid on a smooth 12.7 x 12.7 mm* sirn~at~ electronic chip inside a vertical rectangular channel. Two distinct CHF regimes are established based on flow visualization and experimental data. At low flow velocities, CHF is accompanied by the formation of a continuous vapor blanket...
متن کاملEvaluation of Exerting Force on the Heating Surface Due to Bubble Ebullition in Subcooled Flow Boiling
Vibration characteristics of subcooled flow boiling on thin and long structures such as a heating rod were recently investigated by the author. The results show that the intensity of the subcooled boiling-induced vibration (SBIV) was influenced strongly by the conditions of the subcooling temperature, linear power density and flow velocity. Implosive bubble formation and collapse are the main n...
متن کاملA method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow
Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...
متن کاملDevelopment of a Numerical Model for Subcooled Boiling Flow
Population balance equations combined with a threedimensional two-fluid model are employed to predict bubbly flows with the presence of heat and mass transfer processes. Subcooled boiling flow belongs to this specific category of bubbly flows is considered. The MUSIG (MUltiple-SIze-Group) model implemented in CFX4.4 is further developed to account for the wall nucleation and condensation in the...
متن کاملModeling of Upward Subcooled Flow Boiling of Refrigerant-113 in a Vertical Annulus
In this paper, a modified two-fluid model has been adopted to simulate the process of upward vertical subcooled flow boiling of refrigerant R-113 in a vertical annular channel at low pressure. The modified model considers temperature dependent properties and saturation temperature variation and was validated against a number of published low-pressure subcooled boiling experiments. The results s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Fluid Dynamics & Materials Processing
سال: 2021
ISSN: 1555-2578
DOI: 10.32604/fdmp.2021.013895