Analysis and controller design for stand‐alone VSIs in synchronous reference frame
نویسندگان
چکیده
منابع مشابه
Self-checking synchronous controller design
Efficient models are introduced for totally self-checking/code disjoint (TSCiCD) and strongly fault-secure/strongly code disjoint (SFS/ SCD) synchronous controller models. These models are based on two low-cost, modular, TSC edge-triggered and error-propagating CD flipflops. Properties of the proposed synchronous controller models are proven. The design procedure for these models and their prop...
متن کاملtight frame approximation for multi-frames and super-frames
در این پایان نامه یک مولد برای چند قاب یا ابر قاب تولید شده تحت عمل نمایش یکانی تصویر برای گروه های شمارش پذیر گسسته بررسی خواهد شد. مثال هایی از این قاب ها چند قاب های گابور، ابرقاب های گابور و قاب هایی برای زیرفضاهای انتقال پایاست. نشان می دهیم که مولد چند قاب تنک نرمال شده (ابرقاب) یکتا وجود دارد به طوری که مینیمم فاصله را از ان دارد. همچنین مسایل مشابه برای قاب های دوگان مطرح شده و برخی ...
15 صفحه اولModel Reference Adaptive Fuzzy Controller for Permanent Magnet Synchronous Motor
Conventional control depends on the mathematical model of the plant being controlled. When this model is uncertain, intelligent controllers promise better performance. This paper presents a theoretical study on model reference adaptive fuzzy logic controller for vector controlled Permanent Magnet Synchronous Motor (PMSM) drive. In the proposed system, Fuzzy Logic Control (FLC) is used to implem...
متن کاملSemantic and Ontology Design in Vsis
we tried to increase semantic in the visual stock information system. Firstly, the semantic entity-relation model was given after studying the contents in visual stock information system and the hierarchical classification was shown. Then, semantic metadata and visual ontology was designed. For the implementation of VSIS, ontology reuse was considered which included ontology reuse model, the re...
متن کاملDesign of a Model Reference Adaptive Controller Using Modified MIT Rule for a Second Order System
Sometimes conventional feedback controllers may not perform well online because of the variation in process dynamics due to nonlinear actuators, changes in environmental conditions and variation in the character of the disturbances. To overcome the above problem, this paper deals with the designing of a controller for a second order system with Model Reference Adaptive Control (MRAC) scheme usi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IET Power Electronics
سال: 2017
ISSN: 1755-4535,1755-4543
DOI: 10.1049/iet-pel.2016.0883