An WAMS-Based Online Generators Coherency Identification Approach for Controlled Islanding

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Online Coherence Identification Using Dynamic Time Warping for Controlled Islanding

Controlled islanding is considered to be the last countermeasure to prevent system-wide blackouts in case of cascading failures. It splits the system into self-sustained islands to maintain transient stability at the expense of possible loss of load. Generator coherence identification is critical to controlled islanding scheme as it helps identify the optimal cutset to maintain system transient...

متن کامل

A Wide-Area Measurement Systems-Based Adaptive Strategy for Controlled Islanding in Bulk Power Systems

Controlled islanding is the last countermeasure for a bulk power system when it suffers from severe cascading contingencies. The objective of controlled islanding is to maintain the stability of each island and to keep the total loss of loads of the whole system to a minimum. This paper presents a novel integrated wide-area measurement systems (WAMS)-based adaptive controlled islanding strategy...

متن کامل

Slow Coherency Based Controlled Islanding – A Demonstration of the Approach on the August 14, 2003 Blackout Scenario

This paper demonstrates the use of a slow coherency based generator grouping algorithm and a graph theoretic approach to form controlled islands as a last resort to prevent cascading outages following large disturbances. The proposed technique is applied to a 30,000-bus, 5000-generator, 2004 summer peak load, Eastern Interconnection data and demonstrated on the August 14, 2003 blackout scenario...

متن کامل

An Integrated Passive Islanding Detection Method for Distributed Generators

This study proposes a new islanding detection method for use of grid-interconnected distributed generators (DG). The method is based on two indices: the rate of change of frequency (ROCOF) and the rate of change of voltage (ROCOV). When a DG is grid-interconnected, the ROCOF and ROCOV are lower than the threshold value. In contrast, as an islanding occurs, the ROCOF or ROCOV become much higher ...

متن کامل

Online Aggregation of Coherent Generators Based on Electrical Parameters of Synchronous Generators

This paper proposes a novel approach for coherent generators online clustering in a large power system following a wide area disturbance. An interconnected power system may become unstable due to severe contingency when it is operated close to the stability boundaries. Hence, the bulk power system controlled islanding is the last resort to prevent catastrophic cascading outages and wide area bl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Access

سال: 2020

ISSN: 2169-3536

DOI: 10.1109/access.2020.2993809