An interface for liquid chromatograph/liquid ionization mass spectrometer.
نویسندگان
چکیده
منابع مشابه
Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...
متن کاملA Chemical Ionization Mass Spectrometer for Ambient Measurements of Ammonia
This study presents a chemical ionization mass spectrometer (CIMS) for fast response, in-situ measurements of gas phase ammonia (NH3). The NH3 background level detected with the CIMS ranged between 0.3–1 ppbv, with an uncertainty of 30 pptv under optimized conditions. The instrument sensitivity varied from 4–25 Hz/pptv for >1 MHz of reagent ion signals (protonated ethanol ions), with a 30% unce...
متن کاملTuning of an electrospray ionization source for maximum peptide-ion transmission into a mass spectrometer.
We describe assembly and optimization of a continuous flow nanoelectrospray source for high-performance analysis on a routine basis. It is derived from an inJection adaptable Fine Ionization Source ("JaFIS"), previously shown to be durable and easy to use (Geromanos, S.; et al. Rapid Commun. Mass Spectrom. 1998, 12, 551-556) and now modified for maximum sensitivity. Proper design, manufacturing...
متن کاملAn interface with a linear quadrupole ion guide for an electrospray-ion trap mass spectrometer system.
A new ion sampling interface for an electrospray ionization 3D ion trap mass spectrometer system is described. The interface uses linear rf quadrupoles as ion guides and ion traps to enhance the performance of the 3D trap. Trapping ions in the linear quadrupoles is demonstrated to improve the duty cycle of the system. Dipolar excitation of ions trapped in a linear quadrupole is used to eject un...
متن کاملA field-deployable, chemical ionization time-of-flight mass spectrometer
We constructed a new chemical ionization timeof-flight mass spectrometer (CI-TOFMS) that measures atmospheric trace gases in real time with high sensitivity. We apply the technique to the measurement of formic acid via negative-ion proton transfer, using acetate as the reagent ion. A novel high pressure interface, incorporating two RF-only quadrupoles is used to efficiently focus ions through f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 1988
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.4.467