An Experimental Method to Verify Impulsive Responses on Flat Plate Structure Predicted by Transient Statistical Energy Analysis (TSEA)
نویسندگان
چکیده
منابع مشابه
An experimental method to verify soil conservation by check dams on the Loess Plateau, China.
A successful experiment with a physical model requires necessary conditions of similarity. This study presents an experimental method with a semi-scale physical model. The model is used to monitor and verify soil conservation by check dams in a small watershed on the Loess Plateau of China. During experiments, the model-prototype ratio of geomorphic variables was kept constant under each rainfa...
متن کاملNew Method for Large Deflection Analysis of an Elliptic Plate Weakened by an Eccentric Circular Hole
The bending analysis of moderately thick elliptic plates weakened by an eccentric circular hole has been investigated in this article. The nonlinear governing equations have been presented by considering the von-Karman assumptions and the first-order shear deformation theory in cylindrical coordinates system. Semi-analytical polynomial method (SAPM) which had been presented by the author before...
متن کاملAn Experimental Investigation of the Transient Characteristics on a Flat-Plate Heat Pipe During Startup and Shutdown Operations
This work presents an experimental investigation of the thermal performance of a flatplate heat pipe during startup and shutdown operations. Using the analytical model developed in a previously study, analytical and experimental results on the effect of input power and cooling heat transfer coefficient on the thermal performance of the heat pipe are presented and discussed. The results indicate...
متن کاملAn Experimental Study of Mist / Air Film Cooling On a Flat Plate With Application to Gas
Film cooling is a cooling technique widely used in highperformance gas turbines to protect the turbine airfoils from being damaged by hot flue gases. Motivated by the need to further improve film cooling in terms of both cooling effectiveness and coolant coverage area, the mist/air film cooling scheme is investigated through experiments in this study. A small amount of tiny water droplets (7% w...
متن کاملExperimental Studies On Porous Wick Flat Plate Heat Pipe
In recent years, the use of heat pipe for electronic equipments thermal management has been growing faster to meet the future requirements. The flat plate heat pipes (FPHP) are promising heat transporting devices capable of transmitting high heat fluxes rejected by modern electronic equipments. In the present study, the experimental analysis of the thermal performance of flat plate heat pipe is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
سال: 2011
ISSN: 0387-5024,1884-8354
DOI: 10.1299/kikaic.77.1201