AlphaCAMM, a Micromegas-based camera for high-sensitivity screening of alpha surface contamination

نویسندگان

چکیده

Surface contamination of $^{222}$Rn progeny from the $^{238}$U natural decay chain is one most difficult background contributions to measure in rare event searches experiments. In this work we propose AlphaCAMM, a gaseous chamber read with segmented Micromegas, for direct measurement $^{210}$Pb surface flat samples. The detection concept exploits readout capabilities Micromegas detectors reconstruction $^{210}$Po alpha tracks increase signal-to-background ratio. We report here on design and realization first 26$\times$26 cm$^2$ non-radiopure prototype, which demonstrated by use new algorithm tracks. AlphaCAMM aims minimum detectable activities $100$ nBq cm$^{-2}$ sensitivity upper limits about $60$ at 95\% C.L., requires an intrinsic level $5\times10^{-8}$ alphas s$^{-1}$. discuss prospects reach these goals radiopure prototype currently under construction.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conceptual Design and Simulation of Alpha-Beta Detector for Surface Contamination Measurements

The radioactive contamination measurement is essential in nuclear facilities. Monitoring of low level alpha and beta contamination is possible using light detectors high efficiency. Due to the fact that many detectors canchr('39')t simultaneously discriminate alpha, beta and gamma rays; among existing methods, phoswich detectors would be appropriate option to measure different radioactive conta...

متن کامل

Multi-Camera-based High Precision Measurement Approach for Surface Acquisition

In this paper, a unique 3D shape measurement method for measurement of nearly plain car body parts is proposed. The main advantage of the system is the high accuracy (about 0.1 mm), the high flexibility and the real-time processing. The primary application of the method is the 100% inspection of press formed car parts in the factory since in these cases the high accuracy and the real-time featu...

متن کامل

application of upfc based on svpwm for power quality improvement

در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...

15 صفحه اول

Derivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study

Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy.  An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...

متن کامل

Measurement of surface alpha contamination using electret ion chambers.

Electret ion chambers are inexpensive, light-weight, commercially available, passive charge-integrating devices for accurate measurement of different radiations. Performance of electret ion chambers for surface alpha contamination measurement was evaluated. Ion chambers of two types and electrets of three thicknesses were used for the study. Calibration of the electret ion chambers was performe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Instrumentation

سال: 2022

ISSN: ['1748-0221']

DOI: https://doi.org/10.1088/1748-0221/17/08/p08035