Agreement of phakic and pseudophakic anterior chamber depth measurements in IOLMaster and Pentacam
نویسندگان
چکیده
منابع مشابه
Comparison of anterior chamber depth measurements taken with the Pentacam, Orbscan IIz and IOLMaster in myopic and emmetropic eyes.
PURPOSE This study determined to assess the degree of agreement between anterior chamber depth (ACD) measurements obtained using three different devices and to analyse the relationship between ACD and spherical equivalent (SE) refraction. METHODS In this cross-sectional study, 42 eyes of 42 patients with a mean SE of - 4.69 +/- 4.61 D (range 0.00 D to - 14.88 D) were analysed. Measurements of...
متن کاملValidity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan.
PURPOSE The purpose of this study was to determine the validity and repeatability of anterior chamber depth (ACD) measurements obtained with a novel rotating Scheimpflug camera (Pentacam; Oculus Optikgeräte GmbH, Wetzlar, Germany) to scanning slit topography (Orbscan; Bausch & Lomb, Rochester, NY). METHODS ACD in 60 healthy eyes was measured twice by two independent observers with each modali...
متن کاملComparison of anterior chamber depth measurements using Orbscan II and IOLMaster.
PURPOSE To evaluate and compare anterior chamber depth (ACD) measurements using Orbscan II (Bausch & Lomb, Rochester, NY) and IOLMaster (Carl Zeiss Meditec AG, Jena, Germany). METHODS In this prospective clinical study, the authors measured ACD of 145 phakic eyes of 30 healthy volunteers and 115 patients using Orbscan II and IOLMaster. Average patient age was 52.9+/-19.4 (range 16 to 87) year...
متن کاملAnterior chamber depth measurement: interchangeability between Pentacam and other devices
We reviewed a series of recently published studies in which the anterior chamber depth (ACD) distance was measured by Pentacam or Pentacam HR and compared with other measuring devices. Since some published studies reach contradictory conclusions regarding device interchangeability and include di erent ocular conditions, for instance, phakic eyes, pseudophakic eyes, cataractous eye, and so on, t...
متن کاملCentral corneal thickness, anterior chamber depth, and pupil diameter measurements using Visante OCT, Orbscan, and Pentacam.
PURPOSE To evaluate the agreement among three different optical methods in measuring anterior chamber depth (ACD), central corneal thickness (CCT), and pupil diameter. METHODS One hundred eyes of 50 healthy patients (25 men, 25 women) were enrolled in the study. Mean patient age was 25 years (range: 21 to 32 years). Exclusion criteria were history of any intraocular or corneal surgery, contac...