Adverse Local Tissue Reaction Associated With a Modular Hip Hemiarthroplasty

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corrosion and adverse tissue reaction after modular unipolar hip hemiarthroplasty

Modern unipolar hip hemiarthroplasty, commonly used for displaced femoral neck fracture, is now modular, with both a variable length cobalt-chromium adapter-sleeve and large femoral head. Patients with these modular components may develop symptomatic trunnion corrosion, with elevated serum metal levels. We report the case of an 82-year-old woman, 5.5 years after a modular unipolar hip hemiarthr...

متن کامل

Corrosion and adverse local tissue reaction after total hip arthroplasty with a modular titanium alloy femoral neck

This report describes a case of mechanically assisted crevice corrosion and secondary adverse local tissue reaction in a patient following a total hip arthroplasty, utilizing a modular neck (bi-modular) femoral component. Radiographic evaluation demonstrated a well-positioned, stable, cementless arthroplasty. Upon further evaluation, the patient had elevated serum cobalt and chromium levels, an...

متن کامل

Hip dislocation after modular unipolar hemiarthroplasty.

An institutional review board-approved retrospective review of hip fractures in elderly patients treated with a modular unipolar implant was carried out to identify factors predisposing to dislocation of a hemiarthroplasty. The main outcome measure evaluated was dislocation vs nondislocation. Two hundred seventeen patients underwent the surgery, and 174 were available for review at 6 weeks and ...

متن کامل

Early Complications Following Cemented Modular Hip Hemiarthroplasty

INTRODUCTION Hemiarthroplasty is the recommended treatment for displaced, intracapsular, femoral neck fractures. This study aimed to evaluate the early complications following insertion of the JRI Furlong cemented hemiarthroplasty, a contemporary, modular, double tapered, polished prosthesis. METHOD A series of 459 consecutive patients (May 2006 - June 2009) treated with a JRI hemiarthroplast...

متن کامل

Adverse reaction to metal debris in a painful hemiarthroplasty of the hip

Adverse reaction to metal debris (ARMD) in total hip arthroplasty surgery is a well-known problem. We present the case of a unipolar hemiarthroplasty requiring revision within 18 months of insertion secondary to an adverse reaction to metal debris. This case demonstrates a rare cause for failure of a hemiarthroplasty following a fragility fracture. We feel that ARMD should be considered in all ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Orthopaedics & Related Research

سال: 2013

ISSN: 0009-921X

DOI: 10.1007/s11999-013-3133-1