Active phase control to enhance distance relay in converter-interfaced renewable energy systems
نویسندگان
چکیده
For the distance protection applied in converter-interfaced renewable energy systems, various AC fault ride-through strategies of sources will cause a large phase difference between operating current relay and current, resulting mal-operation relay. To overcome this issue, paper proposes an active control for systems to enhance reliability This scheme firstly calculates by only using local measurements. Then, is eliminated via angle adjustment. verify effectiveness proposed scheme. The performance method tested radial three-terminal system IEEE 14-bus PSCAD/EMTDC.
منابع مشابه
A Buck-Boost Converter; Design, Analysis and Implementation Suggested for Renewable Energy Systems
This work introduces a new non-isolated buck-boost DC-DC converter. Interleaved configuration of the suggested structure increases the voltage conversion ratio. The voltage rate of the suggested converter can be stepped-up and stepped down for lower values of duty-cycle, which causes to decrease in the conduction losses of the system. The voltage conversion ratio of the recommended structure is...
متن کاملA bidirectional DC-DC converter for renewable energy systems
To improve the energy quality, most of the renewable energy systems include an energy storage element charged by the bidirectional DC-DC converter. This paper proposes the bidirectional DC-DC converter which employs the two bridge configuration resonant class-E converters on the both sides of the isolating transformer. The low side converter is controlled as step up and the high side converter ...
متن کاملA Single Phase Grid Connected Converter for Renewable Energy Distributed Systems
In low power renewable systems, a single phase grid-connected converter is usually adopted. This paper deals with a novel five-level converter topology that follows this trend. A review of the state of the art of the five-level topologies and a theoretical power loss comparison with the proposed solution is realized. The proposed converter architecture is based on a full-bridge topology with tw...
متن کاملModel and Control of Renewable Energy Systems
This paper presents a developed method for controlling multi-renewable energy generators. The control system depends basically on three sensors (wind anemometer, solar sensor, and voltage sensor). These sensors represent PLC’s analogue inputs. Controlling the output voltage supply can be achieved by an enhanced method of interlocking between the renewable energy generators, depending on those s...
متن کاملControl and Management of Hybrid Renewable Energy Systems: Review and Comparison of Methods
Hybrid renewable energy systems (HRES) have been introduced to overcome intermittent nature of single-source renewable energy generation. In order to utilize HRES optimally, two issues must be considered: optimal sizing and optimal operation. The first issue has been considered vastly in several articles but the second one needs more attention and work. The performance of hybrid renewable energ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Electrical Power & Energy Systems
سال: 2022
ISSN: ['1879-3517', '0142-0615']
DOI: https://doi.org/10.1016/j.ijepes.2022.108433