Accuracy of various intraocular lens power calculation formulas in steep corneas

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Various Intraocular Lens Power Calculation Formulas in Steep Corneas

PURPOSE To compare the accuracy of four different intraocular lens (IOL) power calculation formulas for eyes with mean keratometry values greater than 46 diopters (D). METHODS Forty five eyes from 45 patients who were candidates for senile cataract surgery with mean keratometry values greater than 46 D were included. Calculation of the IOL power was performed by the Lenstar. The implanted IOL...

متن کامل

Accuracy of Intraocular Lens Power Calculation Formulas in Primary Angle Closure Glaucoma

PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation formulas in eyes with primary angle closure glaucoma (ACG). METHODS This retrospective study compared the refractive outcomes of 63 eyes with primary ACG with the results of 93 eyes with normal open angles undergoing uneventful cataract surgery. Anterior segment biometry including anterior chamber depth, axial length,...

متن کامل

Intraocular Lens Power Calculation Using IOLMaster and Various Formulas in Short Eyes

PURPOSE To evaluate the predictability of intraocular lens (IOL) power calculations using the IOLMaster and four different IOL power calculation formulas (Haigis, Hoffer Q, SRK II, and SRK/T) for cataract surgery in eyes with a short axial length (AL). METHODS The present study was a retrospective comparative analysis which included 25 eyes with an AL shorter than 22.0 mm that underwent uneve...

متن کامل

Accuracy of intraocular lens power calculation in paediatric cataract surgery.

AIMS To determine the accuracy of intraocular lens (IOL) power calculation in a group of pseudophakic children. METHODS A retrospective analysis of biometric and refractive data was performed on 52 eyes of 40 infants and children, who successfully underwent cataract extraction and IOL implantation. The following parameters were included: age at the time of surgery, keratometry, axial length, ...

متن کامل

Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes.

Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Ophthalmic and Vision Research

سال: 2017

ISSN: 2008-322X

DOI: 10.4103/jovr.jovr_20_17