Accuracy of Ultrasound-Guided versus Landmark-Guided Intra-articular Injection for Rat Knee Joints
نویسندگان
چکیده
منابع مشابه
Accuracy of Ultrasound Guided Versus Blind Knee Intra-articular Injection for Knee Osteoarthritis Prolotherapy
Knee osteoarthritis (OA) is one of the most common joint disabling diseases among adult patients. Symptomatic knee OA occurs in 10% men and 13% in women aged 60 years or older but is likely to increase due to the aging of the population and the obesity epidemic [1]. Osteoarthritis (OA) is characterized by progressive loss of articular cartilage, subchondral bone sclerosis, osteophyte formation,...
متن کاملA comparison of ultrasound guided corticosteroid injection vs ozone injection in grade 3 knee osteoarthritis
Background: Osteoarthritis (OA) is a degenerative disease that can cause pain and limited function. One of the non-surgical treatments is intra-articular ozone injection. This study aimed to compare the effect of ultrasound-guided corticosteroid injection with ozone injection in patients with grade 3 osteoarthritis of the knee. Methods: This randomized, double-blind, clinical trial was carried...
متن کاملClinical utility of ultrasound guidance for intra-articular knee injections: a review
Intra-articular corticosteroid and hyaluronic acid injections provide short-term symptom amelioration for arthritic conditions involving structural damage or degenerative changes in the knee. Conventional palpation-guided anatomical injections frequently result in inaccurate needle placement into extra-articular tissue and adjacent structures. The purpose of this review was to determine the eff...
متن کاملEffectiveness of imaging-guided intra-articular injection: a comparison study between fluoroscopy and ultrasound.
OBJECTIVE Compare the effectiveness of ultrasound and fluoroscopy to guide intra-articular injections (IAI) in selected cases. MATERIAL AND METHODS A prospective study in our outpatient clinics at the Rheumatology Division at Universidade Federal de São Paulo (UNIFESP), Brazil, was conducted to compare the short-term (4 weeks) effectiveness of ultrasound and fluoroscopy-guided IAI in patients...
متن کاملAccuracy of Ultrasound-Guided and Non-ultrasound-Guided Botulinum Toxin Injection Into Cadaver Salivary Glands
OBJECTIVE To compare the accuracy of ultrasound (US)-guided and non-US-guided botulinum toxin (BTX) injection into the salivary glands (parotid and submandibular glands) of cadavers. METHODS Two rehabilitation physician injected dye into three sites in the salivary glands (two sites in the parotid gland and one site in the submandibular gland) on one side of each cadaver (one was injected on ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Ultrasound in Medicine & Biology
سال: 2019
ISSN: 0301-5629
DOI: 10.1016/j.ultrasmedbio.2019.06.403