A tomographic image of Indian lithosphere break-off beneath the Pamir-Hindukush region
نویسندگان
چکیده
منابع مشابه
Seismic imaging of the downwelling Indian lithosphere beneath central Tibet.
A tomographic image of the upper mantle beneath central Tibet from INDEPTH data has revealed a subvertical high-velocity zone from approximately 100- to approximately 400-kilometers depth, located approximately south of the Bangong-Nujiang Suture. We interpret this zone to be downwelling Indian mantle lithosphere. This additional lithosphere would account for the total amount of shortening in t...
متن کاملA Tomographic Image of Mantle Structure beneath Southern California
We determined the variations in seismic structure beneath southern California by using a tomographic method of inversion on teleseismic P delays recorded with the Southern California Array. The algorithm employed was a modified form of an Algebraic Reconstruction Technique (ART) used in medical X-ray imaging. Deconvolution with an empirically estimated point spread function was also used to hel...
متن کاملSubduction of the Indian lithosphere beneath the Tibetan Plateau and Burma
Article history: Subduction of the Indian lit Received 8 August 2007 Received in revised form 7 July 2008 Accepted 10 July 2008 Available online 20 July 2008 Editor: C.P. Jaupart
متن کاملPiecewise delamination of Moroccan lithosphere from beneath the Atlas Mountains
The elevation of the intracontinental Atlas Mountains of Morocco and surrounding regions requires a mantle component of buoyancy, and there is consensus that this buoyancy results from an abnormally thin lithosphere. Lithospheric delamination under the Atlas Mountains and thermal erosion caused by upwelling mantle have each been suggested as thinning mechanisms. We use seismic tomography to ima...
متن کاملComputed tomographic anatomy of the abdominal region of cat
The purpose of this study was to identify the anatomic structures of the abdominal region of cat throughcomputed tomography (CT) to be used by veterinary radiologists, clinicians and surgeons. The abdominalregion of four cats were scanned twice, with and without using contrast medium in a same position, usinghigh-resolution imaging protocol. Slice intervals were 11 mm and were adjusted so that ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Geophysical Journal International
سال: 2006
ISSN: 0956-540X,1365-246X
DOI: 10.1111/j.1365-246x.2005.02841.x