منابع مشابه
Waveguide grating mirror in a fully suspended 10 meter Fabry-Perot cavity.
We report on the first demonstration of a fully suspended 10 m Fabry-Perot cavity incorporating a waveguide grating as the coupling mirror. The cavity was kept on resonance by reading out the length fluctuations via the Pound-Drever-Hall method and employing feedback to the laser frequency. From the achieved finesse of 790 the grating reflectivity was determined to exceed 99.2% at the laser wav...
متن کاملA Low-Voltage, Low Quiescent Current, Low Drop-Out Regulator
The demand for low-voltage, low drop-out (LDO) regulators is increasing because of the growing demand for portable electronics, i.e., cellular phones, pagers, laptops, etc. LDO’s are used coherently with dc-dc converters as well as standalone parts. In power supply systems, they are typically cascaded onto switching regulators to suppress noise and provide a low noise output. The need for low v...
متن کاملOptimal Current Meter Placement for Accurate Fault Location Purpose using Dynamic Time Warping
This paper presents a fault location technique for transmission lines with minimum current measurement. This algorithm investigates proper current ratios for fault location problem based on thevenin theory in faulty power networks and calculation of short circuit currents in each branch. These current ratios are extracted regarding lowest sensitivity on thevenin impedance variations of the netw...
متن کاملWater Velocity Measurements in Open Channels Using Volumetric Current Meter (VCM)
An innovative Volumetric Current Meter (VCM) was designed in order to allow quick velocity measurements in open channels. At first, the coefficient of velocity (Cv) of the device was determined through calibration under different water velocities in the laboratory. The measurement performance was verified by measurements performed in similar flows in irrigation channels using an ordinary curren...
متن کاملLiquid Chromatographic Determination of Scopolamine in Hair with Suspended Drop Liquid Phase Microextraction Technique
Hair analysis is used in some branches of alternative medicine as a method of investigation to assist diagnosis. It is very useful when a history of drug use is difficult or impossible to obtain. In this research suspended droplet liquid phase microextraction (SDLME) coupled with high-performance liquid chromatography and photodiode array detection (HPLC-DAD) was used for preconcentration and a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Deep Sea Research and Oceanographic Abstracts
سال: 1963
ISSN: 0011-7471
DOI: 10.1016/0011-7471(63)90363-2