A stability-indicating RP-HPLC assay method for 5-fluorouracil
نویسندگان
چکیده
منابع مشابه
A Stability-Indicating RP-HPLC Assay Method for 5-Fluorouracil
The present study describes the development of a validated RP-HPLC method for the determination of 5-fluorouracil in presence of its degradation products or other pharmaceutical excipients. Stress studies were performed on 5-fluorouracil and it was found that it degrades sufficiently in alkaline conditions, while negligible degradation was observed in acidic, neutral, oxidative and photolytic c...
متن کاملNovel Stability indicating Rp-HPLC Method for the Determination of Assay of Voriconazole in Pharmaceutical Products
A novel stability indicating RP-HPLC method having a very short run time was developed and validated for determination of assay of Voriconazole in bulk solution, lyophilized injectable dosage form and in physiological compatible solutions. The method is novel, rapid, precise, accurate and capable of separating known impurities and degradants from Voriconazole peak proving the stability-indicati...
متن کاملStability-Indicating HPLC Method for Posaconazole Bulk Assay
A stability-indicating liquid chromatographic (LC) method was developed for the determination of posaconazole in bulk. Chromatographic separation was achieved using an isocratic elution in a reversed-phase system, with a mobile phase composed of methanol-water (75:25, v/v), at 1.0 mL min(-1) flow. Samples were exposed to degradation under thermal, oxidative and acid/basic conditions, and no int...
متن کاملA Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملA Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Pharmaceutical Sciences
سال: 2009
ISSN: 0250-474X