A silicon UCN detector with large area and with analysis of UCN polarization
نویسندگان
چکیده
منابع مشابه
A Silicon UCN Detector With Large Area and With Analysis of UCN Polarization
A silicon ultracold neutron (UCN) detector with an area of 45 cm(2) and with a (6)LiF converter is developed at St. Petersburg Nuclear Physics Institute (PNPI). The spectral efficiency of the silicon UCN detector was measured by means of a gravitational spectrometer at Institut Max von Laue - Paul Langevin (ILL). The sandwich-type detector from two silicon plates with a (6)LiF converter placed ...
متن کاملa comparison of teachers and supervisors, with respect to teacher efficacy and reflection
supervisors play an undeniable role in training teachers, before starting their professional experience by preparing them, at the initial years of their teaching by checking their work within the proper framework, and later on during their teaching by assessing their progress. but surprisingly, exploring their attributes, professional demands, and qualifications has remained a neglected theme i...
15 صفحه اول“ UCN anomalous losses and the UCN capture cross section on material defects ” by A .
Comment on the article " UCN anomalous losses and the UCN capture cross section on material defects " by A. Serebrov et al. Abstract We present correct solution of the problem about a scattering of the neutron on a point-like defect existing in a medium and show that this mechanism cannot explain anomalous losses of UCN in storage bottles. In a recent article by Serebrov et al. [1], a possible ...
متن کاملUCN Production With a Single Crystal of Ortho-Deuterium
The present paper reports on the preliminary experimental results concerning a new concept of ultracold neutron production with a single crystal converter of ortho-deuterium lying in the ground rotational state at the low temperature of about 10 K, which should make it possible to utilize a guided cold neutron beam instead of irradiating the converter material in the inside of high radiation fi...
متن کاملUCN anomalous losses and the UCN capture cross-section on material defects
Experimental data shows anomalously large Ultra Cold Neutrons (UCN) reflection losses and that the process of UCN reflection is not completely coherent. UCN anomalous losses under reflection cannot be explained in the context of neutron optics calculations. UCN losses by means of incoherent scattering on material defects are considered and crosssection values calculated. The UCN capture cross-s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Research of the National Institute of Standards and Technology
سال: 2005
ISSN: 1044-677X
DOI: 10.6028/jres.110.041