A new valve for draw-over anaesthesia*

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new valve for draw-over anaesthesia.

The Diamedica non-rebreathing valve has been developed for use in draw-over anaesthesia and can be positioned at the common gas outlet. Its performance was evaluated against the Laerdal, Ruben and Ambu valves under laboratory conditions. Valve resistance during inspiration and expiration was simulated over a range of constant flow conditions. During flows ranging from 5 to 45 l.min(-1) , the Di...

متن کامل

a new approach to credibility premium for zero-inflated poisson models for panel data

هدف اصلی از این تحقیق به دست آوردن و مقایسه حق بیمه باورمندی در مدل های شمارشی گزارش نشده برای داده های طولی می باشد. در این تحقیق حق بیمه های پبش گویی بر اساس توابع ضرر مربع خطا و نمایی محاسبه شده و با هم مقایسه می شود. تمایل به گرفتن پاداش و جایزه یکی از دلایل مهم برای گزارش ندادن تصادفات می باشد و افراد برای استفاده از تخفیف اغلب از گزارش تصادفات با هزینه پائین خودداری می کنند، در این تحقیق ...

15 صفحه اول

Modification of a draw-over vaporizer for use with sevoflurane.

BACKGROUND Draw-over anaesthesia is widely used throughout the developing world, in disaster areas and in military anaesthesia when the supply of pressurized oxygen is unreliable. To date, no draw-over vaporizer has been able to deliver sufficient concentrations of sevoflurane for use in inhalation induction of anaesthesia. A laboratory study to assess the performance of a new vaporizer (DDV2) ...

متن کامل

The Diamedica Draw-Over Vaporizer: a comparison of a new vaporizer with the Oxford Miniature Vaporizer.

The Diamedica Draw-Over Vaporizer (DDV) has been developed as an alternative to the Oxford Miniature Vaporizer (OMV). Both can function as draw-over or plenum vaporizers. The performances of these two vaporizers were compared under conditions simulating intermittent positive pressure ventilation (IPPV) and continuous flow (CF). Series 1 experiments were conducted with the vaporizers in water ba...

متن کامل

New proposal for a retractable roof over a courtyard in Tabriz Islamic Art University

Abstract This paper by reviewing the main examples of small to medium-scale retractable roof structures covering building courtyards is to present an innovative rigid retractable roof system employing spatial frames for a courtyard of an existing building in Tabriz Islamic Art University. The courtyard is currently used for temporary exhibitions and gatherings whenever permitted by environmenta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Anaesthesia

سال: 2010

ISSN: 0003-2409

DOI: 10.1111/j.1365-2044.2010.06501.x