A new classification of talocalcaneal coalitions based on computed tomography for operative planning

نویسندگان

چکیده

Abstract Background Current classifications emphasize the morphology of coalition, however, subtalar joint facets involved should also be emphasized. Objective The objective this study was to develop a new classification system based on articular cover all coalitions and guide operative planning. Methods Patients were diagnosed with talocalcaneal coalition using CT scan, between January 2009 February 2021. classified into four main types according shape nature coalition: I, inferiorly overgrown talus or superiorly calcaneus; II, both calcaneus overgrew; III, an accessory ossicle; IV, complete osseous (I-III are non-osseous coalition). Then each type further divided three subtypes involved. A, involving anterior facets; M, middle facets, P, posterior facets. Interobserver reliability measured at (based shape) subtype (articular facet involved) weighted Kappa. Results There 106 patients (108 ft) included in study. Overall, 8 ft (7.5%) as 75 (69.4%) 7 (6.5%) 18 (16.7%) IV. Twenty-nine (26.9%) only (subtype-P), 74 (68.5%) (subtype-MP), five (4.6%) simultaneously anterior, middle, (subtype-AMP). Type II-MP most common. value Kappa for 0.93 (95%CI 0.86–0.99) ( p <0.001), 0.78 0.66–0.91) <0.001). Conclusion A facilitate planning developed.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A radiologic classification of talocalcaneal coalitions based on 3D reconstruction

PURPOSE Talocalcaneal coalitions can be difficult to detect on plain radiographs, despite obvious clinical findings. The purpose of this study is two-fold: (1) to delineate the benefits of thin-cut computed tomography (CT) and 3D reconstructions and (2) to develop a classification scheme for talocalcaneal coalitions that will provide valuable information for surgical planning. METHODS From 20...

متن کامل

application of upfc based on svpwm for power quality improvement

در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...

15 صفحه اول

Development of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose

Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...

متن کامل

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BMC Musculoskeletal Disorders

سال: 2021

ISSN: ['1471-2474']

DOI: https://doi.org/10.1186/s12891-021-04567-0