A multicenter laboratory assessment of a new automated chemiluminescent assay for ADAMTS13 activity
نویسندگان
چکیده
BackgroundThrombotic thrombocytopenic purpura (TTP) is a rare but potentially fatal disorder caused by ADAMTS13 (a disintegrin and metalloproteinase with thrombospondin type 1 motif, member 13) deficiency. Prompt identification/exclusion of TTP can thus be facilitated rapid testing. The most commonly utilized (enzyme?linked immunosorbent assay [ELISA]–based) takes several hours to perform so does not generally permit testing.ObjectivesTo evaluate the utility new automated test for activity, HemosIL AcuStar Activity assay, based on chemiluminescence able performed an ACL instrument within 33 minutes.Patients/MethodsThis multicenter (n = 8) assessment included testing more than 700 samples, similar numbers prospective 348) retrospective 385) samples. main comparator was Technozym ELISA. We also assessed comparative performance detection inhibitors using Bethesda assay.ResultsOverall, chemiluminescent yielded results ELISA, albeit slight negative bias. inhibitor comparable, positive bias assay. Assay precision both assays, we verified normal reference ranges.ConclusionsThe provided rapidly, which were largely comparable ELISA lower average. Conversely, levels tended identified at higher level Thus, provides fast accurate means quantitate plasma TTP/ADAMTS13 identification/exclusion, other applications.
منابع مشابه
assessment of the effect of honey as a topical therapy for intra oral wound healing in rat.
چکیده ندارد.
15 صفحه اولa new approach to credibility premium for zero-inflated poisson models for panel data
هدف اصلی از این تحقیق به دست آوردن و مقایسه حق بیمه باورمندی در مدل های شمارشی گزارش نشده برای داده های طولی می باشد. در این تحقیق حق بیمه های پبش گویی بر اساس توابع ضرر مربع خطا و نمایی محاسبه شده و با هم مقایسه می شود. تمایل به گرفتن پاداش و جایزه یکی از دلایل مهم برای گزارش ندادن تصادفات می باشد و افراد برای استفاده از تخفیف اغلب از گزارش تصادفات با هزینه پائین خودداری می کنند، در این تحقیق ...
15 صفحه اولEvaluation of a novel automated chemiluminescent assay system for antimicrobial susceptibility testing.
The newly developed Rapid Lumi Eiken/IS60 (RL/IS60) system automatically determines MICs by detecting chemiluminescence produced in the reaction of a chemiluminescent probe and oxygen metabolites from living microorganisms. The present study evaluated this system for accuracy in antimicrobial susceptibility testing. Chemiluminescence intensities after 4 h of cultivation of clinically important ...
متن کاملthe impact of training on second language writing assessment: a case of raters’ biasedness
چکیده هدف اول این تحقیق بررسی تأثیر آموزش مصحح بر آموزش گیرندگان براساس پایایی نمره های آنها در پنج بخش شامل محتوا ، سازمان ، لغت ، زبان و مکانیک بود. هدف دوم این بود که بدانیم آیا تفاوتهای بین آموزشی گیرندگان زن و مرد در پایایی نمرات آنها وجود دارد. برای بررسی این موارد ، ما 90 دانشجو در سطح میانه (متوسط) که از طریق تست تعیین سطح شده بودند انتخاب شدند. بعد از آنها خواستیم که درباره دو موضوع ا...
15 صفحه اولA novel, fully-automated, chemiluminescent assay for the detection of 1,25-dihydroxyvitamin D in biological samples
BACKGROUND 1,25-Dihydroxyvitamin D (1,25-(OH)2D), the hormonal form of vitamin D, is difficult to measure because of its low circulating levels (pg/mL), and similarity to more abundant metabolites. Here a fully-automated chemiluminescent assay that accurately and precisely measures 1,25-(OH)2D is described. METHOD The novel 1,25-(OH)2D assay was conceived based on four pillars: (1) the VDR's ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Thrombosis and Haemostasis
سال: 2021
ISSN: ['1538-7836', '1538-7933']
DOI: https://doi.org/10.1111/jth.15157