A Minimax Entropy Registration Framework for Patient Setup Verification in Radiotherapy
نویسندگان
چکیده
منابع مشابه
Comparison of carina-based versus bony anatomy-based registration for setup verification in esophageal cancer radiotherapy
BACKGROUND To investigate the feasibility and geometric accuracy of carina-based registration for CBCT-guided setup verification in esophageal cancer IGRT, compared with current practice bony anatomy-based registration. METHODS Included were 24 esophageal cancer patients with 65 implanted fiducial markers, visible on planning CTs and follow-up CBCTs. All available CBCT scans (n = 236) were ri...
متن کاملA Novel Approach for the Registration of 2D Portal and 3D CT Images for Treatment Setup Verification in Radiotherapy
In this paper we present a framework to simultaneously segment portal images and register them to 3D treatment planning CT data sets for the purpose of radiotherapy setup verification. Due to the low resolution and low contrast of the portal image, taken with a high energy treatment photon beam, registration to the 3D CT data is a difficult problem. However, if some structure can be segmented i...
متن کاملA Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom
Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...
متن کاملReproducibility of patient setup by surface image registration system in conformal radiotherapy of prostate cancer
BACKGROUND The reproducibility of patient setup for radiotherapy is based on various methods including external markers, X-rays with planar or computerized image acquisition, and, more recently, surface matching imaging. We analyzed the setup reproducibility of 16 patients affected by prostate cancer who underwent conformal radiotherapy with curative intent by using a surface image registration...
متن کاملa framework for identifying and prioritizing factors affecting customers’ online shopping behavior in iran
the purpose of this study is identifying effective factors which make customers shop online in iran and investigating the importance of discovered factors in online customers’ decision. in the identifying phase, to discover the factors affecting online shopping behavior of customers in iran, the derived reference model summarizing antecedents of online shopping proposed by change et al. was us...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Computer Aided Surgery
سال: 1999
ISSN: 1092-9088,1097-0150
DOI: 10.3109/10929089909148182