A Large Aperture Pulsed Septum Magnet for Antiproton Injection into the CERN AC Ring
نویسندگان
چکیده
منابع مشابه
The CERN Low Energy Antiproton Ring has been
The CERN Low Energy Antiproton Ring has been running in its stretcher mode during six physics runs, between July 1983 and December 1984. It has delivered pure and intense beams of antiprotons to sixteen experiments at Five different momenta in the range of 200 to 1500 MeV/c. This paper summarizes the machine par-Formance during these runs and gives a preview of the latest improvements achieved ...
متن کاملNew Synchrotron Injection Septum Magnet at the Aps*
A new direct-drive, out-of-vacuum synchrotron injection septum magnet has been built at the Advanced Photon Source to replace the existing eddy-currentshielded, in-vacuum magnet. We describe the design, assembly, construction, and measurements.
متن کاملOptics for the Antiproton Decelerator at CERN
The former Antiproton Collector (AC) at CERN has been transformed into an Antiproton Decelerator (AD) to supply high quality antiproton beams with a momentum of 100 MeV/c (kinetic energy of 5.3 MeV) [1]. As in AC, antiprotons are injected at 3.57 GeV/c and cooled by stochastic cooling system. To facilitate the deceleration and to prepare a small emittance beam for the experiments, stochastic co...
متن کاملLarge ring polymers align FtsZ polymers for normal septum formation
Cytokinesis in bacteria is initiated by polymerization of the tubulin homologue FtsZ into a circular structure at midcell, the Z-ring. This structure functions as a scaffold for all other cell division proteins. Several proteins support assembly of the Z-ring, and one such protein, SepF, is required for normal cell division in Gram-positive bacteria and cyanobacteria. Mutation of sepF results i...
متن کاملEuropean Organization for Nuclear Research Cern - Sl Division Cern-sl-2000-033 Bt a Novel Eddy Current Septum Magnet for Sps Extraction towards Lhc and Cngs
A new East Fast-Extraction System is under construction in the SPS, to supply particles with a maximum batch length of 7.8 μs and 10.5 μs to the LHC and to CNGS (CERN Neutrino to Gran Sasso), respectively. The extraction septum magnets actually used at the SPS have been designed for slow extraction over several seconds and have large cooling and electrical power demands. A fast system of only 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1985
ISSN: 0018-9499,1558-1578
DOI: 10.1109/tns.1985.4334444