A fast scanner for fluorescence microscopy using a 2‐D CCD and time delayed integration

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MEM-FLIM, a CCD imager for Fluorescence Lifetime Imaging Microscopy

MEM-FLIM, a CCD imager for use in advanced Fluorescence Lifetime Imaging Microscopy (FLIM) applications is presented. A demodulation frequency of 80MHz is achieved with 4V clock swing with an optimized pixel design. An optional electron-multiplication CCD register using a single-poly electrode structure is included in the imager. Introduction A FLIM system requires an imager that can ‘gate’ the...

متن کامل

passivity in waiting for godot and endgame: a psychoanalytic reading

this study intends to investigate samuel beckett’s waiting for godot and endgame under the lacanian psychoanalysis. it begins by explaining the most important concepts of lacanian psychoanalysis. the beckettian characters are studied regarding their state of unconscious, and not the state of consciousness as is common in most beckett studies. according to lacan, language plays the sole role in ...

designing a fast locking pll

a phase-locked loop (pll) based frequency synthesizer is an important circuit that is used in many applications, especially in communication systems such as ethernet receivers, disk drive read/write channels, digital mobile receivers, high-speed memory interfaces, system clock recovery and wireless communication system. other than requiring good signal purity such as low phase noise and low spu...

Gigapixel microscopy using a flatbed scanner

Microscopy imaging systems with a very wide field-of-view (FOV) are highly sought in biomedical applications. In this paper, we report a wide FOV microscopy imaging system that uses a low-cost scanner and a closed-circuit-television (CCTV) lens. We show that such an imaging system is capable to capture a 10 mm * 7.5 mm FOV image with 0.77 micron resolution, resulting in 0.54 gigapixels (10 9 pi...

متن کامل

0.5 gigapixel microscopy using a flatbed scanner.

The capability to perform high-resolution, wide field-of-view (FOV) microscopy imaging is highly sought after in biomedical applications. In this paper, we report a wide FOV microscopy system that uses a closed-circuit-television (CCTV) lens for image relay and a flatbed scanner for data acquisition. We show that such an imaging system is capable of capturing a 10 mm × 7.5 mm FOV image with 0.7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Bioimaging

سال: 1994

ISSN: 0966-9051,1361-6374

DOI: 10.1002/1361-6374(199412)2:4<184::aid-bio3>3.3.co;2-d