A demonstrator for a flexible active microelectrode array with high electrode number

نویسندگان
چکیده

منابع مشابه

Flexible Electrode Array for Retinal Stimulation

In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...

متن کامل

An active, flexible carbon nanotube microelectrode array for recording electrocorticograms.

A variety of microelectrode arrays (MEAs) has been developed for monitoring intra-cortical neural activity at a high spatio-temporal resolution, opening a promising future for brain research and neural prostheses. However, most MEAs are based on metal electrodes on rigid substrates, and the intra-cortical implantation normally causes neural damage and immune responses that impede long-term reco...

متن کامل

flexible electrode array for retinal stimulation

in this work, ito/pet (indium tin oxide / polyethylene terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. flexible ito/pet implantable electrode array for a retina has been developed. the electrode array is fabricated on a thin pet/ito substrate and is encapsulated using, su-8, an insulating material. pet substrate and su-8 po...

متن کامل

Wireless sEMG System with a Microneedle-Based High-Density Electrode Array on a Flexible Substrate

Surface electromyography (sEMG) signals reflect muscle contraction and hence, can provide information regarding a user's movement intention. High-density sEMG systems have been proposed to measure muscle activity in small areas and to estimate complex motion using spatial patterns. However, conventional systems based on wet electrodes have several limitations. For example, the electrolyte enclo...

متن کامل

Flexible three-dimensional microelectrode array for neural applications

A neural electrode array design is proposed with 3 mm long sharpened pillars made from an aluminumbased substrate. The array is composed by 25 electrically insulated pillars in a 5 x 5 matrix, in which each aluminum pillar was precisely machined via dicing saw technique. The result is an aluminum structure with high-aspect-ratio pillars (19:1), each with a tip radius of 10 μm. A thin-film of pl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Current Directions in Biomedical Engineering

سال: 2018

ISSN: 2364-5504

DOI: 10.1515/cdbme-2018-0068