A Compton backscattering polarimeter for measuring longitudinal electron polarization
نویسندگان
چکیده
منابع مشابه
A Compton Backscattering Polarimeter for Measuring Longitudinal Electron Polarization
Compton backscattering polarimetry provides a fast measurement of the polarization of an electron beam in a storage ring. Since the method is non-destructive, the polarization of the electrons can be monitored during internal target experiments. At NIKHEF a Compton polarimeter has been constructed to measure the polarization of the longitudinally polarized electrons stored in the AmPS ring. Fir...
متن کاملA simple optical electron polarimeter
It is pointed out that heavy atoms (i.e. those which have spectroscopically resolvable fine structure) are not required for optical measurements of electron polarisation. A polarimeter which uses helium gas instead of heavy-metal vapour is proposed, and several experimental details are discussed. Optical detection of electron polarisation was first proposed more than a decade ago by Farago and ...
متن کاملMeasuring Electron Response in NaI(Tl) using Compton Coincidence Technique
The scintillation efficiency of electron recoils in liquid xenon (LXe) is not well measured at low energies. The Compton coincidence technique (CCT) is set up using a NaI(Tl) detector and HPGe detector to measure the energy dependence of the light yield in the NaI(Tl) detector from which we can extract the scintillation effieciency. This technique allows for the detection of low energy electron...
متن کاملDeveloping a Compton Polarimeter to Measure Polarization of Hard X-Rays in the 50-300 keV Energy Range
This paper discusses the latest progress in the development of GRAPE (Gamma-Ray Polarimeter Experiment), a hard Xray Compton Polarimeter. The purpose of GRAPE is to measure the polarization of hard X-rays in the 50-300 keV energy range. We are particularly interested in X-rays that are emitted from solar flares and gamma-ray bursts (GRBs). Accurately measuring the polarization of the emitted ra...
متن کاملA cylindrically symmetric "micro-Mott" electron polarimeter.
A small, novel, cylindrically symmetric Mott electron polarimeter is described. The effective Sherman function, Seff, or analyzing power, for 20 kV Au target bias with a 1.3 keV energy loss window is 0.16 ± 0.01, where uncertainty in the measurement is due primarily to uncertainty in the incident electron polarization. For an energy loss window of 0.5 keV, Seff reaches its maximum value of 0.24...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 1998
ISSN: 0168-9002
DOI: 10.1016/s0168-9002(98)00630-5