A Comprehensive Evaluation of Different Power Quantities in DC Electric Arc Furnace Power Supplies

نویسندگان

چکیده

Conventionally, DC arc furnaces are fed by thyristor rectifiers to control the level of current or power transferred load. With advancement high-power transistors, other structures such as diode and choppers have been introduced developed for feeding system electric furnaces. In this paper, effect different supply systems on quality indexes is discussed. regard, two types considered, including a based choppers. addition, methods, constant (CCC) (CPC), applied. For evaluating indexes, voltage harmonic distortion, unbalance current, factor AC side investigated systems. Simulation results were performed with PSCAD/EMTDC software. It shown that superiority in comparison rectifiers. According results, average THD reduced from 16.55% rectifier 8.40% chopper CCC method 19.27% 7.38% CPC method. Moreover, 5.67% 3.02% The result similar Furthermore, specific system, distortion lower case than

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arc Handling Considerations for DC Sputtering Power Supplies

Sputtering is an important physical vapor deposition (PVD) method in the manufacture of many products. However, sputtering processes are prone to arcing, which can cause damage to the work piece. Therefore, arcs must be detected and extinguished in a timely manner to minimize damage. Instantaneous arc rate and total arcs per process step are useful data for assessing PVD chamber health, and det...

متن کامل

Recycling Evaluation of Mill Scale in Electric Arc Furnace

A considerable amount of mill scale is generated from steelmaking plants annually. Although some industries use it as raw material however, since it contains iron in the form of FeO, Fe2O3, and Fe3O4, it can be considered as a valuable metallurgical raw material for iron and steelmaking industry as well. Thus, the aim of this study was to evaluate the possibility, efficiency, and consequences o...

متن کامل

Low Noise Dc Power Supplies

− Some measuring systems are very sensitive on disturbances incoming from power supplies. If no accumulators are used for their power supply, which ensure a minimum signal noise and transmission jamming signal from power network, special power supplies have to be constructed for them. An example of a possible influence of a disturbance, which spreads along to the power supply on high pure sine-...

متن کامل

Performance evaluation of composite filter for power quality improvement of electric arc furnace distribution network

Electric arc furnace (EAF) is one of the responsible cause for deteriorating power quality in the distribution network by, introducing harmonics, propagating voltage flicker and causing unbalance in voltages and currents. This paper presents performance evaluation of composite filter (CF) for power quality improvement of EAF distribution network. The performance of CF is evaluated in terms of h...

متن کامل

An Evaluation of Battery Power Supplies for Electric Railguns

This paper describes an analytical feasibility study of the use of chemical storage batteries as the power supply for an electric railgun. The railguns studied are capable of accelerating 1 to 10 kg projectiles to 10 km/sec. Batteries were studied because they offer extremely high energy storage density although they operate at low voltage. Thus, an inductive store must be used to provide pulse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2023

ISSN: ['1996-1073']