A Comparison of Mammographic X-Ray Spectra
نویسندگان
چکیده
منابع مشابه
simulation and comparison of radiology x-ray spectra
monte carlo method is a very accurate method to optimize medical diagnostic radiology spectra and simulation of radiation transportation. using mcnp code, radiology and mammography attenuated x-rayspectraweresimulated.the ipem report number 78 was used as a reference to compare with the geant4 and mcnp simulations because of its popularity and wide availability. the results of geant4 in 40kev s...
متن کاملDirect Measurement of Mammographic X-Ray Spectra with a Digital CdTe Detection System
In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate X-ray spectroscopy in mammography (1-30 keV). The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and hig...
متن کاملX-ray spectra calculation for different target-filter of mammograms using MCNP Code
ABSTRACTBackground: An electron beam generated X-ray spectrum consists of characteristic X-ray and continuous bermsstrahlung. The aim of this research is calculating and comparing X-ray spectra for different target filter of mammograms. Materials and Methods: Monte Carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the X-ray spectra. MC...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملCalculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography
Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1978
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00001364982