A Combination Water Softener and Storage Tank
نویسندگان
چکیده
منابع مشابه
Bus water storage tank as a reservoir of Legionella pneumophila.
Health concerns associated with Legionnaires' disease have been identified as an area of the increasing public and professional interest. Any natural water or man-made water systems worldwide might be reservoirs of Legionellae. We presented a sporadic, community-acquired case of Legionnaires' disease caused by Legionellapneumophila serogroup 1 in a bus driver who used water for hand and face wa...
متن کاملMicrobiological study of water-softener resins.
Microbial identification using effluents backflushed from exhausted urban and rural tank resins and cleaned resins containing the sulfonated copolymer of styrene and divinylbenzene (SDB) were completed, along with microbial assessment of the concentrated stock salt brine. Forty-four different bacterial and fungal genera were identified. Extensive biochemical and animal virulence tests completed...
متن کاملCFD Modelling of an Underground Water Tank Heat Storage System
In this work, CFD is used to simulate the flow in an existing thermal labyrinth located at the basement of a hospital building. This labyrinth is an underground channel equipped with water tanks to increase the thermal mass and reduce the heating and cooling demand of the building. Thermal energy storage in the water tanks is a complex heat transfer phenomena involving turbulent forced convecti...
متن کاملStorage Tank Design
A calculus problem arising in the operation of a storage tank for a chemical processing plant is described. Constructing an appropriate gauge for the storage tank requires computing the volume of water residing inside a tilted cylindrical pipe. The following calculus problem arose in the engineering design of a storage tank facility, and is possibly more interesting and challenging for students...
متن کاملMeasured and Modeled Charging of a Stratified Chilled Water Thermal Storage Tank with Slotted Pipe Diffusers
As part of ASHRAE Research Project 1185, field data from the constant flow rate charging of a stratified chilled water storage tank with double-ring octagonal slotted-pipe diffusers serving a university chilled water system were compared with results of a transient axisymmetric computational fluid dynamics (CFD) model. Charge processes at flows near design flow rate and 50% of design were model...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Industrial & Engineering Chemistry
سال: 1914
ISSN: 0095-9014,1943-2968
DOI: 10.1021/ie50069a016