A charge-metering method for voltage-mode neural stimulation
نویسندگان
چکیده
منابع مشابه
A charge-metering method for voltage-mode neural stimulation
Electrical neural stimulation is the technique used to modulate neural activity by inducing an instantaneous charge imbalance. This is typically achieved by injecting a constant current and controlling the stimulation time. However, constant voltage stimulation is found to be more energy-efficient although it is challenging to control the amount of charge delivered. This paper presents a novel,...
متن کامل16-Channel biphasic current-mode programmable charge balanced neural stimulation
BACKGROUND Neural stimulation is an important method used to activate or inhibit action potentials of the neuronal anatomical targets found in the brain, central nerve and peripheral nerve. The neural stimulator system produces biphasic pulses that deliver balanced charge into tissue from single or multichannel electrodes. The timing and amplitude of these biphasic pulses are precisely controll...
متن کاملA Method for Hardware Metering
In this paper we present a hardware metering method to meter or monitor legitimate use of integrated circuits embedded in a computer system. The motivation for this work comes from fabless semiconductor design business/operation model which has become very effective and popular in last few years. A fabless design house produces a design and gives it to a foundry to manufacture the final chip. O...
متن کاملPower Snapshot Analysis: a New Method for Analyzing Low Voltage Grids Using a Smart Metering System
The subject of this paper is to describe the method newly developed within the research project ISOLVES (Innovative Solutions to Optimize LV Electricity Systems). The objectives are to study LV grids in detail and to close gaps of knowledge about impacts on voltage levels caused by asymmetric load or feed, and real grounding systems. Therefore a smart metering system (AMIS-Siemens) has to be up...
متن کاملOptimized Fuzzy Controller Design in Unbalanced Voltage Drop Mode for Dynamic Voltage Restorer
The loss of balanced voltages involves a voltage drop due to symmetric three-phase errors, or the initiation of high-power three-phase loads or symmetric three-phase switches. While these events in an unbalanced way lead to asymmetric voltage drops. Voltage drops can cause asymmetric load on the power grid, the occurrence of volatility, and even network power outage. One of the most common ways...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Neuroscience Methods
سال: 2014
ISSN: 0165-0270
DOI: 10.1016/j.jneumeth.2013.11.028