40 MHz Swept-Source Optical Coherence Tomography at 1060 nm Using a Time-Stretch and Supercontinuum Spectral Broadening Dynamics

نویسندگان

چکیده

We present an akinetically swept light source based on a spectrally broadened mode-locked laser in all normal dispersion optical fiber followed by linear dispersive time stretch and regenerative amplification stage. Developed for ultrafast swept-source coherence tomography (SS-OCT), the enables demonstration of A-scan rate at 40 MHz with 12 μm axial resolution. Through A-scans captured from fast-moving object, we demonstrate that high-speed OCT is possible 1 wavelength architecture which not intrinsically bandwidth limited. The therefore shows promising route to achieving high resolution OCT.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo human retinal and choroidal vasculature visualization using differential phase contrast swept source optical coherence tomography at 1060 nm

A differential phase contrast (DPC) method is validated for in vivo human retinal and choroidal vasculature visualization using high-speed swept-source optical coherence tomography (SS-OCT) at 1060 nm. The vasculature was identified as regions of motion by creating differential phase variance (DPV) tomograms: multiple B-scans were collected of individual slices through the retina and the varian...

متن کامل

In vivo human choroidal vascular pattern visualization using high-speed swept-source optical coherence tomography at 1060 nm.

PURPOSE To investigate the retinal and choroidal vascular pattern, structure, and thickness using high-speed, high axial resolution, swept-source optical coherence tomography (SS-OCT) at 1060 nm, demonstrating enhanced penetration through all choroidal layers. METHODS An ophthalmic SS-OCT system was developed operating at 57,000 A-lines/s with 5.9 μm axial resolution and was used to collect 3...

متن کامل

Ultrahigh-speed optical coherence tomography utilizing all-optical 40 MHz swept-source.

We present an ultrahigh-speed optical coherence tomography (OCT) based on an all-optical swept-source with an A-scan rate of 40 MHz. The inertia-free swept-source, which has its output power of 41.2 mW and tuning range of 40 nm and high scan linearity in wavenumber with Pearson's correlation coefficients r of 0.9996, consists of a supercontinuum laser, an optical band-pass filter, a linearly ch...

متن کامل

Differential phase-contrast, swept-source optical coherence tomography at 1060 nm for in vivo human retinal and choroidal vasculature visualization.

Human retinal and choroidal vasculature was visualized by a differential phase-contrast (DPC) method using high-speed, swept-source optical coherence tomography (SS-OCT) at 1060 nm. The vasculature was recognized as regions of motion by creating differential phase-variance (DPV) tomograms: multiple B-scans of individual slices through the retina were collected and the variance of the phase diff...

متن کامل

Visualizing the Choriocapillaris Under Drusen: Comparing 1050-nm Swept-Source Versus 840-nm Spectral-Domain Optical Coherence Tomography Angiography

PURPOSE To investigate the appearance of choriocapillaris (CC) flow under drusen by comparing long-wavelength (1050 nm) swept-source optical coherence tomography (SS-OCT) angiography with shorter-wavelength (840 nm) spectral-domain (SD) OCT angiography. METHODS Patients with drusen imaged on both devices on the same day were selected and graded. Ambiguous OCT angiography (OCTA) signal loss wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Photonics Journal

سال: 2022

ISSN: ['1943-0655', '1943-0647']

DOI: https://doi.org/10.1109/jphot.2022.3226820