3D polymer gel dosimetry and Geant4 Monte Carlo characterization of novel needle based X-ray source
نویسندگان
چکیده
منابع مشابه
Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملA CUDA Monte Carlo simulator for radiation therapy dosimetry based on Geant4
1 Institute for Computational & Mathematical Engineering, Stanford University, 475 Via Ortega, Stanford, CA 94306, USA 2 High Energy Accelerator Research Organization, KEK, 1-1 Oho, Tsukuba, Ibaraki, 305-0801, JAPAN SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA Electrical Engineering, Nagaoka University of Technology, 1603-1 Kamitomioka, Nagaoka, Niigata, ...
متن کاملCALDose_X online: Web-based, real time Monte Carlo calculations for patient dosimetry in X-ray diagnosis
CALDose_X 5.0 is a software package for the calculations of organ and tissue absorbed doses, as well as cancer risks for patients submitted to examinations of conventional radiography which can be downloaded from www.caldose.org. The program is based on conversion coefficients (CCs) between organ and tissue absorbed dose and measurable quantities, calculated with the MASH and FASH adult referen...
متن کاملCharacterization of X-Ray Diamond Detector by Monte Carlo Method
The use of diamond as material for X-ray detector is subject of investigation and practice in radiotherapy, space and material science and technology. This paper presents the results of application of Monte Carlo method for simulation of photon transport through diamond detector. The aim is restitution and demonstrating of numerical technique for characterization of electrical properties for di...
متن کاملThermoluminescent and Monte Carlo dosimetry of IR06‐P103d brachytherapy source
This work presents experimental dosimetry results for a new 103Pd brachytherapy seed, in accordance with the AAPM TG-43U1 recommendation that all new low-energy interstitial brachytherapy seeds should undergo one Monte Carlo (MC) and at least one experimental dosimetry characterization. Measurements were performed using TLD-GR200A circular chip dosimeters using standard methods employing thermo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2010
ISSN: 1742-6596
DOI: 10.1088/1742-6596/250/1/012069