Positive Expiratory Pressure (PEP) versus Conventional Chest Physiotherapy in Pediatric Patients with Acute Exacerbation of Cystic Fibrosis
Background Pulmonary involvement is the main cause of mortality in cystic fibrosis (CF). Airway clearance techniques are non-pharmacological complement options for CF patients. The aim of this study was to evaluate the short-term outcome of airway cleaning treatment in patients with cystic fibrosis in a children's hospital. Materials and Methods This clinical trial study conducted on 40 CF pati...
متن کاملPositive expiratory pressure and oscillatory positive expiratory pressure therapies.
Airway clearance techniques, historically referred to as chest physical therapy, have traditionally consisted of a variety of breathing maneuvers or exercises and manual percussion and postural drainage. The methods and types of airway clearance techniques and devices have rapidly increased in an effort to find a more efficacious strategy that allows for self-therapy, better patient adherence a...
متن کاملPositive end-expiratory pressure.
PURPOSE OF REVIEW In the last 2 years, several reports have dealt with recruitment/positive end-expiratory pressure (PEEP) selection. Most of them confirm previous results and few add new information. RECENT FINDINGS It has been definitely confirmed that opening pressures are different throughout the acute respiratory distress syndrome lung parenchyma, ranging from 5-10 up to 30-40 cmH2O. The...
متن کاملPhysiological responses to positive expiratory pressure breathing: a comparison of the PEP bottle and the PEP mask.
BACKGROUND In the intensive care unit we have observed that patients have different adherence to 2 commonly used positive-expiratory-pressure (PEP) therapy devices: the PEP bottle and the PEP mask. The reason for this difference is not clear. METHODS In a randomized prospective study, we made continuous recordings of airway pressure and airflow, with 20 healthy volunteers, with the PEP bottle...
متن کاملFlow resistance of expiratory positive-pressure systems.
We measured the flow-resistance of five commercially available 10 cm H2O expiratory positive-pressure (EPP) valves (n = five per valve type) at bias flows of between 0 and 2,000 ml/s. We found that individual valves of each type and manufacturer functioned similarly. Different valve types, however, functioned differently: with one type, system pressure was higher than rated (p less than 0.05), ...