1385 poster COMMISSIONING OF PENELOPE AND GATE MONTE CARLO MODELS FOR 6 AND 18 MV PHOTON BEAMS FROM THE SIEMENS ARTISTE LINAC
نویسندگان
چکیده
منابع مشابه
Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams
Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...
متن کاملMonte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams
Objective The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data. Methods The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perc...
متن کاملQuality Assurance of LINAC by Analyzing the Profile of 6-MV and 10-MV Photon Beams Using Star Track Device
Introduction: According to the American Society of Radiation Oncology, all patients receive radiation therapy during their illness, where radiation is delivered by the medical linear accelerator (Linac). The aim of this study was to evaluate the quality assurance (QA) of the Linac in analyzing the used dose profile in the treatment of cancer tumors. Materi...
متن کاملEstimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at 6 and 18 MV Linac Energies using Monte Carlo Simulation Methods
Background: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...
متن کاملThe plastic tray effect on the spectrum of photoneutrons prudused by 18 MV medical linac using the Monte Carlo method
Introduction: One of the important problems of using high energy linacs is the production of photoneutrons. High energy medical linacs produce secondary neutrons. These phtoneutrons increase patient dose Materials and Methods: In this study, the effect of plastic trays on spectrum of photoneutrons produced by 18MV linac is investigated using the MCNP4C code...