13) VENTILATION CHARACTERISTICS OF THE VENTILATORS

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bi-PAP, nasal ventilation, and body ventilators.

Communications to the Editor bronchoscope. They did not emphasize the increased risk from general anesthesia (two myocardial inlarctions, cardiac arrhythmia), the need for prolonged mechanical ventilation, and the increased cost oilusing general versus topical anesthesia, as well as monitoring in the intensive care unit for two days. Curiously, the authors did not find an advantage of the rigid...

متن کامل

Performance of ventilators for noninvasive positive-pressure ventilation in children.

The aim of the present study was to evaluate the performance characteristics of all the ventilators proposed for home noninvasive positive-pressure ventilation in children in France. The ventilators (one volume-targeted, 12 pressure-targeted and four dual) were evaluated on a bench which simulated six different paediatric ventilatory patterns. For each ventilator, the quality of the inspiratory...

متن کامل

Evaluation of ventilators for mouthpiece ventilation in neuromuscular disease.

BACKGROUND Daytime mouthpiece ventilation is a useful adjunct to nocturnal noninvasive ventilation (NIV) in patients with neuromuscular disease. The aims of the study were to analyze the practice of mouthpiece ventilation and to evaluate the performance of ventilators for mouthpiece ventilation. METHODS Practice of mouthpiece ventilation was assessed by a questionnaire, and the performance of...

متن کامل

Ventilators for noninvasive ventilation to treat acute respiratory failure.

The application of noninvasive ventilation (NIV) to treat acute respiratory failure has increased tremendously both inside and outside the intensive care unit. The choice of ventilator is crucial for success of NIV in the acute setting, because poor tolerance and excessive air leaks are significantly correlated with NIV failure. Patient-ventilator asynchrony and discomfort can occur if the phys...

متن کامل

ASSISTED VENTILATION Performance of mechanical ventilators at the patient’s home: a multicentre quality control study

Background: Quality control procedures vary considerably among the providers of equipment for home mechanical ventilation (HMV). Methods: A multicentre quality control survey of HMV was performed at the home of 300 patients included in the HMV programmes of four hospitals in Barcelona. It consisted of three steps: (1) the prescribed ventilation settings, the actual settings in the ventilator co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Transactions of the Architectural Institute of Japan

سال: 1961

ISSN: 0387-1185,2433-0027

DOI: 10.3130/aijsaxx.67.0_90