1074 AXILLARY VEIN PUNCTURE VERSUS CEPHALIC VEIN CUTDOWN FOR CARDIAC IMPLANTABLE ELECTRONIC DEVICE IMPLANTATION: A METANALYSIS

نویسندگان

چکیده

Abstract Introduction Transvenous lead implantation for pacemaker is commonly performed by the cephalic vein cutdown (CVC), subclavian (SVP), or axillary puncture (AVP)(1). However, CVC AVP should be considered as first choice, according to last guidelines, due high rate of complications and pneumothorax SVP. Objective To compare efficacy safety compared with CIED a meta-analysis. Methods We systematically searched Medline, Embase Cochrane electronic databases up September 5th, 2022, studies that evaluated reporting at least one clinical outcome interest. The primary was acute procedural success. secondary outcomes were pneumothorax, failure, pocket hematoma/bleeding, device infection, total procedure time, venous access time fluoroscopy time. effect size estimated using random-effect model Risk Ratio (RR) relative 95% Confidence Interval (CI). Results A 8 included enrolling 1926 patients 3532 leads average age 72.3±14.8 years. showed significant increase in success (95.7% vs 76.1%; RR: 1.24; CI: 1.09-1.40; p=0.001), (Figure 1). Total (Mean Difference [MD]: -8.25 min; 95%CI: -10.23- -6.27; p<0.0001) Venous (MD: -6.24 -7.01- -5.47; significantly shorter CVC. No differences found between (RR: 0.72; 0.13 - 4.0; p=0.71), failure 0.58; 0.23-1.48; p=0.26), hematoma/bleeding 0.15- 2.23; p=0.43), infection 0.95; 0.14- 6.60; p=0.96) -0.24 -0.75- 0.28; p=0.36). Conclusion Our meta-analysis proved improves reduces Figure 1 – Forest plots comparing Acute Procedural Success Axillary Vein Puncture Versus Cephalic Cutdown.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left axillary pacemaker generator implantation with a direct puncture of the left axillary vein.

BACKGROUND Pacemaker generators are routinely implanted in the anterior chest. However, where to place the generator may need to be considered from the mental, functional, and cosmetic standpoints. METHODS In this study, we performed the left axillary pacemaker generator implantation with a direct puncture of the left axillary vein in 40 consecutive patients, and evaluated the late safety and...

متن کامل

Cephalic vein cutdown for totally implantable central venous port in children: a retrospective analysis of prospectively collected data.

BACKGROUND The jugular vein cutdown for a totally implantable central venous port (TICVP) has 2 disadvantages: 2 separate incisions are needed and the risk for multiple vein occlusions. We sought to evaluate the feasibility of a cephalic vein (CV) cutdown in children. METHODS We prospectively followed patients who underwent a venous cutdown for implantation of a TICVP between Jan. 1, 2002, an...

متن کامل

Axillary vein puncture without contrast venography for pacemaker and defibrillator leads implantation.

BACKGROUND Axillary vein puncture has been demonstrated to be an effective method for pacemaker and defibrillator leads implantation, without the complications encountered with the standard intrathoracic approach. OBJECTIVE Different techniques have been adopted for the cannulation of the axillary vein. We report our experience using the outer edge of the first rib below the inferior border o...

متن کامل

Venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator lead implantation.

AIMS Contrast-guided axillary vein puncture is commonly used for pacemaker or defibrillator lead implantation. Venous spasm during contrast-guided axillary vein puncture has been reported rarely. We investigated the incidence of venous spasm during contrast-guided axillary vein puncture and the impact of venous spasm on axillary vein puncture. METHODS AND RESULTS Seventy-four consecutive pati...

متن کامل

A safe and effective method for pacemaker implantation in children Axillary vein puncture for device implantation and use of 4F catheter- delivered pacing leads in children

Background: Contrast-guided axillary vein puncture has gained popularity for pacemaker and implantable cardioverter defibrillator (ICD) implantation in adults owing to its low risk profile, and could be an alternative to subclavian vein puncture, which is commonly performed in children. The Medtronic 3830 lead is a 4.1F lumenless catheter-delivered lead which may be particularly well-suited for...