100. Analysis of CT-image using Effective Atomic Number and Electron Density. (2)
نویسندگان
چکیده
منابع مشابه
A new method to measure electron density and effective atomic number using dual-energy CT images.
The purpose of this work is to present a new method to extract the electron density ([Formula: see text]) and the effective atomic number (Z eff) from dual-energy CT images, based on a Karhunen-Loeve expansion (KLE) of the atomic cross section per electron. This method was used to calibrate a Siemens Definition CT using the CIRS phantom. The predicted electron density and effective atomic numbe...
متن کاملReply to Comment on 'A new method to measure electron density and effective atomic number using dual-energy CT images'.
In this note, we would like to respond to the comments made by Professor Bouchard on our recent published work and clarify some aspects of it.
متن کاملElectron Density Distributions and Atomic Charges *
Accurate electron densities and X-ray form factors of Li, Be, F and their ions have been calculated. Electron correlation, crystal fields and ionic charge transfer change the form factors by up to a few percent, mainly in the range of sin 0 /k < | Ä " 1 . Although electron correlation and crystal fields are small perturbations, their effects on the density and form factor are not additive. Dens...
متن کاملDiscussion of Electron Induced Atomic Number Contrast
In this paper, atomic number (Z) contrast from electron induced images is revisited. Z contrast obtained with a scanning electron microscope (SEM) is generally associated with the collection of backscattered electrons (BSEs) and is considered to exhibit a monotonic increase in BSE signal with Z [1]. However, there is no monotonic relationship of the backscattering coefficient, η, with Z at elec...
متن کاملanalysis of ruin probability for insurance companies using markov chain
در این پایان نامه نشان داده ایم که چگونه می توان مدل ریسک بیمه ای اسپیرر اندرسون را به کمک زنجیره های مارکوف تعریف کرد. سپس به کمک روش های آنالیز ماتریسی احتمال برشکستگی ، میزان مازاد در هنگام برشکستگی و میزان کسری بودجه در زمان وقوع برشکستگی را محاسبه کرده ایم. هدف ما در این پایان نامه بسیار محاسباتی و کاربردی تر از روش های است که در گذشته برای محاسبه این احتمال ارائه شده است. در ابتدا ما نشا...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1990
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00003322225