Background—A better knowledge of patient x-ray dose and the associated radiation risk in pediatric interventional cardiology is warranted in view of the extensive use of x-rays and the higher radiosensitivity of children. In the present study, -H2AX foci were used as a biomarker for radiation-induced effects. Patient-specific dose was assessed and radiation risks were estimated according to the...
متن کاملEvaluating Gamma-H2AX Expression as a Biomarker of DNA Damage after X-ray in Angiography Patients
Objective: Coronary heart disease (CHD) is one of the most common diseases. Coronary angiography (CAG) is an important apparatus used to diagnose and treat this disease. Since angiography is performed through exposure to ionizing radiation, it can cause harmful effects induced by double-stranded breaks in DNA which is potentially life-threatening damage. The aim of the present study is to inves...
متن کاملγ-H2AX as a protein biomarker for radiation exposure response in ductal carcinoma breast tumors: Experimental evidence and literature review
Background: H2AX is a histone variant that is systematically found and ubiquitously distributed throughout the genome. DNA double-strand breaks (DSBs) induce phosphorylation of H2AX at serine 139 (γH2AX), an immunocytochemical assay with antibodies recognizing γH2AX has become the gold standard for the detection of DSBs. The importance of this assay to investigate different individu...
متن کاملγ-h2ax as a protein biomarker for radiation exposure response in ductal carcinoma breast tumors: experimental evidence and literature review
background: h2ax is a histone variant that is systematically found and ubiquitously distributed throughout the genome. dna double-strand breaks (dsbs) induce phosphorylation of h2ax at serine 139 (γh2ax), an immunocytochemical assay with antibodies recognizing γh2ax has become the gold standard for the detection of dsbs. the importance of this assay to investigate different individual responses...
متن کاملPhysician and patient exposure during cardiac catheterization.
A survey of the literature was conducted to establish the anticipated ranges of exposure to both physicians and patients during cardiac catheterization. A brief explanation of a technic for using time-lapse photography and a computer model for exposure calculation is presented. The thermoluminescent dosimeter (TLD) results used as controls for exposure values calculated by the developed techniq...