Journal: :مهندسی قدرت ایران 0
reza shariatinasab university of birjand, iran z ejtemaee university of birjand, iran j gholinezhad university of birjand, iran

power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. the resonant overvoltages may destroy the insulation between turns and cause to insul...

M. Heidarzadeh, M. R. Besmi,

Overvoltage distribution along the transformer winding must be uniform to certify the safety of the operation of the power transformer. Influence of the parameters variation on the impulse voltage distribution (IVD) in disk winding transformer is going to be analyzed which hasn’t been analyzed on this type of winding in the previous papers. In this research, a transformer with disk winding and ...

J Gholinezhad Reza Shariatinasab, Z Ejtemaee

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...

J Gholinezhad Reza Shariatinasab, Z Ejtemaee

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...

Nowadays, multi-winding transformers are widely used in traction systems and steel manufacturer.  Multi-winding transformer that is used in these systems has especial geometry (that is usually called as split-winding transformer) and encounters with serious magnetic and thermal difficulties. According to the special geometry of split-winding transformer, studding the transient thermal behavior ...

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

A.K Gautam, V Mishra,

In this Article dispersion characteristic of conventional optical waveguide with helical winding at core – cladding interface has been obtained. The model dispersion characteristics of optical waveguide with helical winding at core-cladding interface have been obtained for five different pitch angles. This paper includes dispersion characteristics of optical waveguide with helical winding, and ...

2013
V.P.Prawyn Jeba

The wind turbine converts the wind energy into electrical energy, wherein the electrical machines are coupled with wind turbines for this conversion. The electrical machines are liable to meet with faults, but to regain the system reliability the faults should be detected earlier. According to studies of electrical power research institute (EPRI) most of the faults in electrical motors are crea...

2007
MOHAMMAD S. NADERI M. VAKILIAN T. R. BLACKBURN T. B. PHUNG MEHDI S. NADERI

Partial discharges (PD) are recognized as the main cause of the inner insulation deterioration process in power transformers. Therefore, the optimum inner insulation design is one of the challenges a transformer designer is faced with. Transformer strength, especially during transient conditions, is a criterion for transformer insulation designers. This challenge has made designers initiate and...

2016
G. H. Kusumadevi G. R. Gurumurthy

Transient overvoltages appearing at line terminal of power transformer HV windings can cause failure of winding insulation. The failure can be from winding to ground or between turns or sections of winding. In most of the cases, failure from winding to ground can be detected by changes in the wave shape of surge voltage appearing at line terminal. However, detection of insulation failure betwee...